Practical and illustrated summary of updated BI-RADS for ultrasonography

نویسنده

  • Jiyon Lee
چکیده

The American College of Radiology released the fifth edition of the Breast Imaging-Reporting and Data System (BI-RADS) in 2014 (copyright 2013), which includes the expanded second edition of the ultrasound BI-RADS lexicon. This review provides a practical summary of the updated lexicon, including selective illustrations with original clinical images, a discussion of overarching concepts, and examples of current clinical applications.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

BI-RADS 3: Current and Future Use of Probably Benign

Purpose of Review Probably benign (BI-RADS 3) causes confusion for interpreting physicians and referring physicians and can induce significant patient anxiety. The best uses and evidence for using this assessment category in mammography, breast ultrasound, and breast MRI will be reviewed; the reader will have a better understanding of how and when to use BI-RADS 3. Recent Findings Interobserv...

متن کامل

Nonpalpable BI-RADS 4 breast lesions: sonographic findings and pathology correlation.

PURPOSE We aimed to evaluate ultrasonography (US) findings for Breast Imaging Reporting and Data System (BI-RADS) category 4 lesions using BI-RADS US lexicon and determine the positive and negative predictive values (PPV and NPV) of US with respect to biopsy results. METHODS Sonograms of 186 BI-RADS 4 nonpalpable breast lesions with a known diagnosis were reviewed retrospectively. The morphol...

متن کامل

Evaluation of morphometric parameters calculated from breast lesion contours at ultrasonography in the distinction among BI-RADS categories*

Objective: To assess the performance of morphometric parameters calculated from breast lesion contours at ultrasonography, in the quantification of morphological features and in the distinction among BI-RADS categories 2, 3, 4 and 5. Materials and Methods: The present casuistry included 40 cases, with orthogonal imaging of patients submitted to surgery. Based on the lesions segmentation, the fo...

متن کامل

Usefulness of ultrasound elastography in reducing the number of Breast Imaging Reporting and Data System category 3 lesions on ultrasonography

PURPOSE To evaluate the negative predictive value (NPV) of ultrasound (US) elastography for non-palpable Breast Imaging Reporting and Data System (BI-RADS) category 3 lesions on ultrasonography and to determine whether US elastography is helpful in reducing the number of BI-RADS category 3 lesions on ultrasonography. METHODS Two hundred seventy-six consecutive, non-palpable BI-RADS category 3...

متن کامل

Breast ultrasound diagnostic performance and outcomes for mass lesions using Breast Imaging Reporting and Data System category 0 mammogram

PURPOSE To evaluate the outcomes and diagnostic performance of ultrasonography after a Breast Imaging Reporting and Data System (Bi-RADS) category 0 mammogram. MATERIAL AND METHODS This retrospective study reviewed 4,384 consecutive patients who underwent a screening mammography from January 2005 to July 2006; 391 of the 4,384 exams were classified as Bi-RADS category 0. After exclusions, 241...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 36  شماره 

صفحات  -

تاریخ انتشار 2017