Error Measurement for a Portable Tonometer

نویسندگان

  • Peter Marchetto
  • Tara Alvarez
  • Richard Greene
  • Gordon Thomas
چکیده

Most patients with glaucoma exhibit elevated intraocular pressure (IOP). A cost effective device that allows the patient to measure IOP at regular intervals may reduce vision loss. This research tested the Bausch & Lomb Proview self tonometer against a calibrated force meter. It further compared the Proview tonometer with results from the clinical gold standard, the Goldmann tonometer. Results show that the Proview tonometer has inaccuracies in calibration and uncertainties in clinical applications. If the Proview’s calibration is corrected (using our results, e.g.), and the inaccuracies can be reduced, a device like the Proview has the potential to be clinically useful.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Goldmann tonometer error correcting prism: clinical evaluation

PURPOSE Clinically evaluate a modified applanating surface Goldmann tonometer prism designed to substantially negate errors due to patient variability in biomechanics. METHODS A modified Goldmann prism with a correcting applanation tonometry surface (CATS) was mathematically optimized to minimize the intraocular pressure (IOP) measurement error due to patient variability in corneal thickness,...

متن کامل

Have You Tested Your Goldmann Tonometer Today?

Intraocular pressure (IOP) is the only known modifiable risk factor for glaucoma. Besides being a cornerstone in glaucoma management, accurate measurement of IOP forms an important component of routine ophthalmic evaluation. Despite the innovation of various newer tonometers, Goldmann applanation tonometer is still considered the Gold standard for IOP measurement. However, there are several rep...

متن کامل

Perkins hand-held applanation tonometer. A clinical evaluation.

MANY ophthalmologists measure intra-ocular pressure with the Goldmann tonometer. It is neither portable nor capable of being used with the patient supine, which is disadvantageous in glaucoma screening programmes when it is often necessary to examine sick patients in their homes. An applanation tonometer, which is portable and can be used with the patient supine, sitting, or even standing, has ...

متن کامل

Non-ionizing electromagnetic waves measurement and monitoring Systems

In this paper, portable and online monitoring systems for non-ionizing EMF measurement, as well as some measurement results in Tehran are discussed. First of all, standards and recommendations related to EMF monitoring, measurement and exposure such as ISIRI No.8567, ICNIRP guideline and ITU-K.83 are reviewed. Then, technical facts and operation of portable device and monitoring station are int...

متن کامل

EPISCLERAL VENOUS PRESSURE IN TONOGRAPHY * t BY ARTHUR

DURING the 11 years in which the clinical measurement of facility of outflow by means of tonography has been practised, various workers have sought to elucidate and correct the sources of error inherent in this method. One of the assumptions originally made concerning tonography was that the episcleral venous pressure was not disturbed during the measurement. Friedenwald (Grant, 1951) and Becke...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2002