Rectal wall dose estimation in intracavitary brachytherapy: A preliminary comparison of an in-house rectal wire versus ICRU 38 recommendations (Short report)
نویسندگان
چکیده
Background: In intracavitary brachytherapy for gynecological cancers, various techniques are used to locate the anterior rectal wall nearest to the sources but there is no consensus on the best method to do so. This study aimed to compare a technique used rou nely in some centers that employs a wire marker to locate the posi on of the maximum rectal dose point, versus the method recommended by the ICRU Report 38. Materials and Methods: In a preliminary prospec ve study on 34 intracavitary inser ons for pa ents with cervical or endometrial cancer, treated at our center based on the Manchester system, the dose distribu ons were obtained from a treatment planning system following the input of scanned orthogonal anteroposterior and lateral radiographs. For each case, an in‐house marked wire was inserted in the rectal lumen and the doses were calculated on several points along the wire seen on the radiographs, to obtain the maximum dose. For the same inser ons, the ICRU method was also applied by considering the rectal wall hot spot as a point 0.5 cm posterior to the posterior vaginal wall (visualized on the radiographs by vaginal packing material containing contrast medium). Results: Averaged over all inser ons, mean rectal wall hot spot dose calculated using the posi onal informa on obtained by the wire technique was lower by 28.6% than that given by the ICRU method (P < 0.001). Conclusion: Our ini al results add evidence to the sugges on that the wire technique underes mates the rectal wall hot spot dose significantly compared to the ICRU method.
منابع مشابه
Rectal wall dose estimation in intracavitary brachytherapy: A preliminary comparison of an in-house rectal wire versus ICRU 38 recommendations
Background: In intracavitary brachytherapy for gynecological cancers, various techniques are used to locate the anterior rectal wall nearest to the sources but there is no consensus on the best method to do so. This study aimed to compare a technique used routinely in some centers that employs a wire marker to locate the position of the maximum rectal dose point, versus the method recommended b...
متن کاملNon isocentric film-based intracavitary brachytherapy planning in cervical cancer: a retrospective dosimetric analysis with CT planning
PURPOSE To compare intracavitary brachytherapy dose estimation for organs at risk (bladder and rectum) based on semi-orthogonal reconstruction of radiographs on non-isocentric X-ray unit and Computed Tomography (CT) - based volumetric planning in cervical cancer. MATERIAL AND METHODS Bladder and rectal points as per International Commission on Radiation Units and Measurements (ICRU) report 38...
متن کامل”Maximum dose” points in cervical and endometrial cancer medium dose rate brachytherapy
Background: Best dose distribution in target volume and control of Organ at Risk (OAR) dose are the two main goals in brachytherapy. Materials and Methods: In this study in vivo dosimetry in 4 rectal points was performed by Transillumination Dosimeter (TLD) s and the measured doses were compared in different patients. One point was reported to have the maximum dose in each patient and the very ...
متن کاملDosimetric evaluation of rectum and bladder using image-based CT planning and orthogonal radiographs with ICRU 38 recommendations in intracavitary brachytherapy
The purpose is to compare CT-based dosimetry with International Commission on Radiation Units and Measurements (ICRU 38) bladder and rectum reference points in patients of carcinoma of uterine cervix treated with intracavitary brachytherapy (ICA). Twenty-two consecutive patients were evaluated. Orthogonal radiographs and CT images were acquired and transferred to PLATO planning system. Bladder ...
متن کاملRectal and Bladder Dose Measurements in the Intracavitary Applications of Cervical Cancer Treatment with HDR Afterloading System: Comparison of TPS Data with MOSFET Detector
Background: Intracavitary brachytherapy plays a major role in management of cervical carcinoma. Assessment of dose received by OAR’s therefore becomes crucial for the estimation of radiation toxicities in HDR brachytherapy. Objective: Purpose of this study is to evaluate the role of in vivo dosimetry in HDR brachytherapy and to compare actual doses delivered to OAR’ s with those calculate...
متن کامل