Removal of Well-Fixed Cementless Acetabular Components in Revision Total Hip Arthroplasty.

نویسندگان

  • Muyibat A Adelani
  • Stuart B Goodman
  • William J Maloney
  • James I Huddleston
چکیده

The Zimmer Explant Acetabular Cup Removal System (Warsaw, Indiana) has been touted as a superior method for removing well-fixed cementless acetabular components while minimizing bone loss; however, no comparative data support this. This study compares bone loss following the removal of well-fixed acetabular components with Aufranc gouges and with the Explant System. A review of 623 revision total hip arthroplasties (THAs) at the authors' institution between 2002 and 2013 identified cases involving the revision of well-fixed cementless hemispherical acetabular components for any reason except infection. Twenty-four cases using Aufranc gouges and 27 cases using the Explant System were included. The following surrogates for bone loss were used: (1) the difference between the initial acetabular component outer diameter (OD) and the final reamer OD; (2) the difference between the initial acetabular component OD and the new acetabular component OD; and (3) the use of impaction bone grafting. A 2-tailed Wilcoxon-Mann-Whitney test was used to assess the difference in bone loss between the 2 groups. The use of bone grafting was compared between the groups with the chi-square test. The median differences between the initial acetabular component and the final reamer (P=.004), as well as between the initial and new acetabular components (P=.002), were 2 mm less with the Explant System. Hips in the Aufranc group were more likely to have bone grafting (54% vs 26%; P=.04). These results suggest less bone loss when removing well-fixed acetabular components with the Zimmer Explant System compared with Aufranc gouges.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Cementless Hip Arthroplasty in Southern Iran, Midterm Outcome and Comparison of Two Designs

Background: Cementless hip prosthesis was designed to provide biologic fixation, without the use of cement. The second generation components have shown more reliable bone ingrowths and survival rates. We are reporting a midterm result of two designs of cementless prosthesis in a unique culture with different social habits and expectations.Methods: 52 primary cementless total hip arthroplasty in...

متن کامل

Removal of well-fixed, cementless, acetabular components in revision hip arthroplasty.

Removal of well-fixed, cementless, acetabular components during revision arthroplasty remains a challenging problem. Further damage to host bone may limit options for reconstruction and compromise the long-term result of the revision operation. We report the results of 31 hips with well-fixed, cementless sockets which were removed using a new cup extraction system. In all hips the socket was re...

متن کامل

Acetabular components in total hip arthroplasty: is there evidence that cementless fixation is better?

BACKGROUND The use of cementless acetabular components in total hip arthroplasty has gained popularity over the past decade. Most total hip arthroplasties being performed in North America currently use cementless acetabular components. The objective of this systematic review and meta-analysis was to compare the survivorship and revision rate of cemented and cementless acetabular components util...

متن کامل

Cementless Total Hip Arthroplasty After an Iatrogenic Subtrochanteric Fracture due to Hardware Removal: A Case Report

Introduction: Total hip arthroplasty (THA) after proximal femoral fixation is a challenging procedure due to possible hardware-related complications. Case presentation: A 78-year-old female with hip osteoarthritis had a proximal femoral osteotomy fixed using a blade plate in the same femur 41 years ago. A two-step approach was planned. After a challenging...

متن کامل

Cementless Hip Arthroplasty in Southern Iran, Midterm Outcome and Comparison of Two Designs

BACKGROUND Cementless hip prosthesis was designed to provide biologic fixation, without the use of cement. The second generation components have shown more reliable bone ingrowths and survival rates. We are reporting a midterm result of two designs of cementless prosthesis in a unique culture with different social habits and expectations. METHODS 52 primary cementless total hip arthroplasty i...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Orthopedics

دوره 39 2  شماره 

صفحات  -

تاریخ انتشار 2016