Translational Computed Tomography: A New Data Acquisition Scheme

نویسندگان

  • Theobald FUCHS
  • Tobias SCHÖN
  • Randolf HANKE
چکیده

Today, most computed tomography (CT) systems acquire projection data from several hundred to thousands of directions by employing multi-row (2-D) or flat-panel detectors (cone-beam for 3-D imaging). It is important to notice the following fact: modern CT systems all rely on a rotational movement. The most widely utilized reconstruction algorithms, as for instance the well-known Feldkamp method, are based on filtered back projection (FBP). These algorithms afford a series of projection images covering an angular range of at least 180°.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A new scheme for view-dependent data differentiation in fan-beam and cone-beam computed tomography.

In computed tomography, analytical fan-beam (FB) and cone-beam (CB) image reconstruction often involves a view-dependent data differentiation. The implementation of this differentiation step is critical in terms of resolution and image quality. In this work, we present a new differentiation scheme that is robust to changes in the data acquisition geometry and to coarse view sampling. Our scheme...

متن کامل

FPGA based data acquistion and digital pulse processing for PET and SPECT

The most important aspects of nuclear medicine imaging systems such as Positron Emission Tomography (PET) or Single Photon Emission Computed Tomography (SPECT) are the spatial resolution and the sensitivity (detector efficiency in combination with the geometric efficiency). Considerable efforts have been spent during the last two decades in improving the resolution and efficiency by developing ...

متن کامل

Helical cone-beam computed tomography image reconstruction algorithm for a tilted gantry with N-PI data acquisition

Guang-Hong Chen University of Wisconsin–Madison Department of Medical Physics Madison, Wisconsin 53704 and University of Wisconsin–Madison Department of Radiology Madison, Wisconsin 53792 E-mail: [email protected] Abstract. We present a cone-beam image reconstruction algorithm for helical CT scanning with a tilted gantry and N-PI data acquisition. When the gantry is tilted, the effective source t...

متن کامل

Top-level design and pilot analysis of low-end CT scanners based on linear scanning for developing countries.

The goal is to develop new architectures for computed tomography (CT) which are at an ultra-low-cost for developing countries, especially in rural areas. The proposed general scheme is inspired by the recently developed compressive sensing and interior tomography techniques, where the data acquisition system targets a region of interest (ROI) to acquire limited and truncated data. Similar to li...

متن کامل

Dictionary-Learning-Based Reconstruction Method for Electron Tomography

Electron tomography usually suffers from so-called “missing wedge” artifacts caused by limited tilt angle range. An equally sloped tomography (EST) acquisition scheme (which should be called the linogram sampling scheme) was recently applied to achieve 2.4-angstrom resolution. On the other hand, a compressive sensing inspired reconstruction algorithm, known as adaptive dictionary based statisti...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2010