PURPOSE To investigate the reliability of partial coherence laser interferometry for optical biometry in highly myopic eyes. METHODS Axial length measurements by the IOLMaster (Carl Zeiss Meditec, Germany) with signal-to-noise ratio (SNR) ≥2 were performed in 52 consecutive myopic subjects with axial length ≥26.5 mm and 45 emmetropic patients before cataract surgery. Axial length measurements and SNR were analyzed and compared among the two study groups. RESULTS Axial length measurements were feasible in 46 of 52 (88.5%) highly myopic eyes and in 41 of 45 (91.1%) eyes with normal axial length. To achieve two reliable axial length values with SNR ≥2, a mean number of 2.06±0.25 measurements was necessary in myopic eyes and 2.10±0.37 in emmetropic counterparts. Mean SNR after two measurements was 4.98±2.44 in myopic eyes versus 5.56±2.32 in control eyes. Even though successful measurement was independent of preoperative visual acuity, patients with visual acuity better than 20/63 showed significantly higher SNR values. CONCLUSIONS Partial coherence laser interferometry shows satisfying feasibility and good signal quality for axial length determination in highly myopic eyes with stable retinal condition and clear media.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Glaucoma-Induced Optic Disc Morphometric Changes and Glaucoma Diagnostic Ability of Heidelberg Retina Tomograph II in Highly Myopic Eyes

PURPOSE This study was performed to first investigate the morphological differences in the optic nerve head between highly myopic non-glaucomatous controls and highly myopic glaucomatous eyes in comparison with the differences between emmetropic non-glaucomatous controls and emmetropic glaucomatous eyes using confocal scanning laser ophthalmoscopy. Further, the ability of the apparatus in glauc...

متن کامل

Pseudoaccommodative cornea treatment using the NIDEK EC-5000 CXIII excimer laser in myopic and hyperopic presbyopes.

PURPOSE To investigate the refractive outcomes and spherical aberration of multifocal LASIK to create a distant-dominant center and near-dominant periphery in hyperopic, myopic, and emmetropic presbyopia. METHODS One hundred ninety-five eyes with myopic presbyopia and 119 eyes with hyperopic or emmetropic presbyopia that underwent LASIK or epithelial LASIK (epi-LASIK) were assessed out to 3 m...

متن کامل

Choroidal thickness and high myopia: a case-control study of young Chinese men in Singapore.

PURPOSE To determine the distribution of choroidal thickness (CT) and ocular factors associated with CT in high myopic eyes in comparison with emmetropic eyes of young healthy adults. METHODS A case-control study of 648 young, male subjects, including 520 high myopes and 128 emmetropes. Choroidal imaging was performed using enhanced depth imaging spectral domain optical coherence tomography. ...

متن کامل

Prediction accuracy of intraocular lens power calculation methods after laser refractive surgery

BACKGROUND This study aimed to evaluate the prediction accuracy of postoperative refractions using partial coherence interferometry (IOL-Master) and applanation ultrasound (AL-3000) assisted with corneal topography (TMS-4) in eyes that had undergone myopic laser-assisted in situ keratomileusis (LASIK). METHODS Haigis-L formula, Koch-Maloney method using Haigis formula, Shammas clinically deri...

متن کامل

Submicrometer precision biometry of the anterior segment of the human eye.

PURPOSE To demonstrate the feasibility of measuring the anterior structures of the human eye by partial coherence interferometry and to determine its precision for eyes under normal and cycloplegic conditions. METHODS The dual-beam version of partial coherence interferometry, a recently developed noninvasive optical ranging technique, enables high resolution measurements of several intraocula...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2014