Central vault after phakic intraocular lens implantation: correlation with anterior chamber depth, white-to-white distance, spherical equivalent, and patient age.

نویسندگان

  • José F Alfonso
  • Luis Fernández-Vega
  • Carlos Lisa
  • Paulo Fernandes
  • Jorge Jorge
  • Robert Montés Micó
چکیده

PURPOSE To compare the central postoperative vault of a phakic intraocular lens (pIOL) to correct myopia, myopic astigmatism, and hyperopia and identify ocular and lens parameters that might predict the vault amount. SETTING Fernández-Vega Ophthalmological Institute, Oviedo, Spain. DESIGN Cohort study. METHODS Three months after implantation of Implantable Collamer Lens pIOLs to correct myopia, hyperopia, and myopic astigmatism, central vault was measured using optical coherence tomography. Patients were divided into groups according to the preoperative anterior chamber depth (ACD) to compare the effects of ACD, white-to-white (WTW) distance, and lens diameter on postoperative pIOL vault. RESULTS Hyperopic pIOLs had statistically significantly lower vault followed by myopic pIOLs and toric pIOLs, which had a higher mean value and narrower range (260 to 860 μm). Measured vaults had a positive correlation with preoperative ACD (r = .32, P<.001) and WTW (r = .29, P<.001) and a negative correlation with preoperative spherical equivalent (SE) (r = -0.21, P<.001) and patient age (r = -0.12, P=.025). Eyes with a vault of 250 μm or less had a shallower ACD than eyes with a vault between 250 μm and 750 μm (mean difference -0.11 mm; P=.012) and those with a vault greater than 750 μm (mean difference -0.25 mm; P<.001). CONCLUSIONS Central vaulting was lower in hyperopic eyes. Current nomograms for pIOL diameter selection based on ACD and WTW might yield ideal vault and may have to be adjusted for older patients, shallower ACD, lower WTW, and lower SE.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Endothelial distance after phakic iris-fixated intraocular lens implantation: a new safety reference

PURPOSE To evaluate the distance between the endothelial surface of the cornea to the anterior edge of an Artiflex® phakic intraocular lens (IOL) implant to improve the safety profile of this implant. METHODS This is a retrospective clinical case series of 45 patients who had Artiflex phakic IOL implantation (Artiflex p-IOL) with a follow-up period of 3 years. A Pentacam HR imaging system was...

متن کامل

Correction of moderate to high hyperopia with an implantable collamer lens: medium-term results.

PURPOSE To evaluate the medium-term results of phakic posterior chamber implantable collamer lens implantation to correct moderate and high hyperopia. METHODS In this retrospective study, patients were treated for hyperopia with the Visian Implantable Collamer Lens (ICH model V3; STAAR Surgical AG, Nidau, Switzerland). Examined parameters were manifest refraction spherical equivalent, uncorre...

متن کامل

Three-year follow-up of the Artisan phakic intraocular lens for hypermetropia.

PURPOSE We report the postoperative results of the Artisan Hyperopia phakic intraocular lens (IOL; model 203W; Ophtec, Groningen, The Netherlands). DESIGN Prospective, nonrandomized trial. PARTICIPANTS Twenty-six eyes of 13 self-selected patients with refractive error ranging from +3.00 to +11.00 diopters (D). INTERVENTION Patients with hypermetropia were implanted with the Artisan Hypero...

متن کامل

Comparison of early changes in and factors affecting vault following posterior chamber phakic Implantable Collamer Lens implantation without and with a central hole (ICL V4 and ICL V4c)

BACKGROUND To objectively compare the early changes in vault over time following implantation of an Implantable Collamer Lens without (ICL V4) and with (ICL V4c) a central hole and the respective factors affecting vault change in moderate to high myopia. METHODS This prospective study comprised of 38 eyes of 38 patients implanted with ICL V4 and 39 eyes of 39 patients implanted with ICL V4c i...

متن کامل

Reversal of myopic anisometropic amblyopia with phakic intraocular lens implantation.

PURPOSE To report a case of reversal of myopic anisometropic amblyopia with phakic intraocular lens implantation. METHODS A 6-year-old boy with anisometropic amblyopia with spherical equivalent refraction of right eye: -14.00 -3.00 x 100 degrees, left eye: -0.50 -3.25 x 90 degrees, was treated for 2 years with occlusion to the left eye, with poor results. Refractive surgery was planned becaus...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of cataract and refractive surgery

دوره 38 1  شماره 

صفحات  -

تاریخ انتشار 2012