Effects of mouth washing procedures on removal of budesonide inhaled by using Turbuhaler.

نویسندگان

  • Haruko Yokoyama
  • Yoshikazu Yamamura
  • Takeshi Ozeki
  • Tatsuji Iga
  • Yasuhiko Yamada
چکیده

Mouth washing after inhalation of corticosteroids is effective for prevention of local adverse effects. We determined the amounts of drug residues remaining on the oropharyngeal mucosa following inhalation of budesonide (BUD) via a Turbuhaler (BUD-TH) (100 microg). Further, we studied the effects of mouth washing on the removal of drug residues by quantification of BUD in expectorated wash solution using an HPLC method. The amount of BUD recovered after gargling and rinsing for 5 s each was 19.4+/-9.4 microg, as compared to 23.8+/-13.6 microg after rinsing alone for 10 s and 18.3+/-8.9 microg after gargling alone for 10 s, though the differences were not significant. Our results indicated that about 20% of the dose was remaining on the oropharyngeal mucosa after inhalation. In a comparison of washing times, the amounts of BUD recovered were 26.3+/-3.2 microg after gargling and rinsing for 3 s each, and 19.4+/-9.3 microg after those for 5 s each. As for the effect of lag time before beginning mouth washing, the ratio of BUD recovered following mouth washing with a lag time of 1 min was 73.2%, while it was reduced to 27.8% after 10 min, as compared to immediate mouth washing following administration. Our results suggest that the amount of BUD removed by mouth washing is associated with the lag time between inhalation and mouth washing, however, not with the duration of mouth washing. We concluded that immediate mouth washing after inhalation is most useful for the removal of drugs following BUD-TH administration.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of a volumatic spacer and mouth rinsing on systemic absorption of inhaled corticosteroids from a metered dose inhaler and dry powder inhaler.

BACKGROUND High doses of inhaled corticosteroids are absorbed systemically and may cause long term side effects. As rinsing the mouth out after use and inhaling through a spacing device may reduce systemic absorption this has been further investigated. METHODS Three crossover studies were carried out to assess the effect of budesonide given by dry powder inhaler (Turbuhaler) with and without ...

متن کامل

Lung deposition of budesonide inhaled via Turbuhaler: a comparison with terbutaline sulphate in normal subjects.

We wanted to evaluate whether lung deposition of budesonide and terbutaline sulphate differs, and to determine lung deposition of budesonide inhaled at different peak inspiratory flows, through Turbuhaler. Lung deposition of budesonide, a lipophilic substance, and of terbutaline sulphate, a hydrophilic substance, was therefore compared, after administration via an inspiratory flow-driven, multi...

متن کامل

Once-daily budesonide inhalation powder (Pulmicort Turbuhaler) improves health-related quality of life in adults previously receiving inhaled corticosteroids.

In the treatment of asthma, the conventional measures used to monitor a patient's progress and health status do not address the impact of functional impairments associated with the disease that may affect the patient's daily life. Unlike those measures, health-related quality of life (HRQL) reflects the physical, psychological, and social difficulties a patient perceives on a day-to-day basis. ...

متن کامل

Lung deposition and systemic availability of fluticasone Diskus and budesonide Turbuhaler in children.

Pharmacokinetic studies can be used to measure lung dose of inhaled drugs. The aim of this study was to compare the lung deposition of budesonide (BUD) inhaled from Turbuhaler (AstraZeneca, Lund, Sweden) and fluticasone propionate (FP) inhaled from Diskus (GlaxoSmithKline, London, UK) and to assess if the study design used for pharmacokinetic studies can be simplified. Plasma levels of BUD and ...

متن کامل

Lung deposition of budesonide from Turbuhaler is twice that from a pressurized metered-dose inhaler P-MDI.

The pulmonary and systemic availability of budesonide after inhalation from a dry powder inhaler, Turbuhaler, and from a pressurized metered-dose inhaler (P-MDI) were compared in healthy volunteers. Two different methods were used to assess pulmonary availability: 1) calculated from the systemic availability corrected for an oral availability of 13% (n = 24); and 2) after blocking of gastrointe...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Yakugaku zasshi : Journal of the Pharmaceutical Society of Japan

دوره 127 8  شماره 

صفحات  -

تاریخ انتشار 2007