Towards a realistic biomechanical model of the thumb: the choice of kinematic description may be more critical than the solution method or the variability/uncertainty of musculoskeletal parameters.

نویسندگان

  • Francisco J Valero-Cuevas
  • M Elise Johanson
  • Joseph D Towles
چکیده

A biomechanical model of the thumb can help researchers and clinicians understand the clinical problem of how anatomical variability contributes to the variability of outcomes of surgeries to restore thumb function. We lack a realistic biomechanical model of the thumb because of the variability/uncertainty of musculoskeletal parameters, the multiple proposed kinematic descriptions and methods to solve the muscle redundancy problem, and the paucity of data to validate the model with in vivo coordination patterns and force output. We performed a multi-stage validation of a biomechanical computer model against our measurements of maximal static thumbtip force and fine-wire electromyograms (EMG) from 8 thumb muscles in each of five orthogonal directions in key and opposition pinch postures. A low-friction point-contact at the thumbtip ensured that subjects did not produce thumbtip torques during force production. The 3-D, 8-muscle biomechanical thumb model uses a 5-axis kinematic description with orthogonal and intersecting axes of rotation at the carpometacarpal and metacarpophalangeal joints. We represented the 50 musculoskeletal parameters of the model as stochastic variables based on experimental data, and ran Monte Carlo simulations in the "inverse" and "forward" directions for 5000 random instantiations of the model. Two inverse simulations (predicting the distribution of maximal static thumbtip forces and the muscle activations that maximized force) showed that: the model reproduces at most 50% of the 80 EMG distributions recorded (eight muscle excitations in 5 force directions in two postures); and well-directed thumbtip forces of adequate magnitude are predicted only if accompanied by unrealistically large thumbtip torques (0.64+/-0.28Nm). The forward simulation (which fed the experimental distributions of EMG through random instantiations of the model) resulted in misdirected thumbtip force vectors (within 74.3+/-24.5 degrees from the desired direction) accompanied by doubly large thumbtip torques (1.32+/-0.95Nm). Taken together, our results suggest that the variability and uncertainty of musculoskeletal parameters and the choice of solution method are not the likely reason for the unrealistic predictions obtained. Rather, the kinematic description of the thumb we used is not representative of the transformation of net joint torques into thumbtip forces/torques in the human thumb. Future efforts should focus on validating alternative kinematic descriptions of the thumb.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Anatomical Variability Naturally Leads to Multimodal Distributions of Denavit - Hartenberg Parameters for the Human Thumb

—A realistic biomechanical model of the thumb would enhance our understanding of the functional consequences of orthopedic and neurological diseases, and of treatments. Our work has shown that a kinematic description with five orthogonal and intersecting axes of rotation cannot predict realistic thumbtip forces. An alternative kinematic description proposes five axes of rotation that need not b...

متن کامل

Monitoring process variability: a hybrid Taguchi loss and multiobjective genetic algorithm approach

The common consideration on economic model is that there is knowledge about the risk of occurrence of an assignable cause and the various cost parameters that does not always adequately describe what happens in practice. Hence, there is a need for more realistic assumptions to be incorporated. In order to reduce cost penalties for not knowing the true values of some parameters, this paper aims ...

متن کامل

Efficient Solution Procedure to Develop Maximal Covering Location Problem Under Uncertainty (Using GA and Simulation)

  In this paper, we present the stochastic version of Maximal Covering Location Problem which optimizes both location and allocation decisions, concurrently. It’s assumed that traveling time between customers and distribution centers (DCs) is uncertain and described by normal distribution function and if this time is less than coverage time, the customer can be allocated to DC. In classical mod...

متن کامل

Solving a Bi-Objective Multi-Product Vehicle Routing Problem with Heterogeneous Fleets under an Uncertainty Condition

This paper presents a novel bi-objective multi-product capacitated vehicle routing problem with uncertainty in demand of retailers and volume of products (UCVRP) and heterogeneous vehicle fleets. The first of two conflict fuzzy objective functions is to minimize the cost of the used vehicles, fuel consumption for full loaded vehicles and shortage of products. The second ...

متن کامل

A New Approach for Finding an Optimal Solution for Grey Transportation Problem

In ordinary transportation problems, it is always supposed that the mileage from every source to every destination is a definite number. But in special conditions, such as transporting emergency materials when natural calamity occurs or transporting military supplies during wartime, carrying network may be destroyed, mileage from some sources to some destinations are no longer definite. It is u...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of biomechanics

دوره 36 7  شماره 

صفحات  -

تاریخ انتشار 2003