Ultrasonic imaging system by using optical pulse compression.

نویسندگان

  • T Sato
  • M Ueda
  • H Tada
چکیده

The conventional ultrasonic imaging techniques including the holographic one give a high resolution in angle, but a relatively poor resolution in range, because the resolution in range is obtained only by use of selective focus or parallax useful only with a small focal ratio. This paper presents the principle and some experimental results of new ultrasonic imaging techniques that use a linear FM ultrasonic pulse and a pulse of light. This technique gives a high resolution both in angle and in range. It may be considered to be an application of pulse compression techniques used in chirp radar to the ultrasonic imaging. It has an image-forming capability as well as a range-discriminating capability.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optical pulse compression based on nonlinear silicon waveguides and chirped Bragg gratings

Due to the growing demand for higher bandwidth, employing optical devices instead of electronic devices in data transmission systems has attracted much attention in recent years. Optical switches, modulators and wavelength converters are a few examples of the required optical devices. CMOS compatible fabrication of these devices, leads to much more growing of this technology. Optical pulse comp...

متن کامل

Pulse compression technique applied to ultrasonic nondestructive testing of concrete

The pulse compression technique is successfully and widely used in many fields for improving the signal to noise ratio (SNR); which is especially useful when the environment is noisy and the SNR is poor. Since high frequency ultrasound is strongly attenuated in concrete, only low frequency ultrasound can be used in ultrasonic nondestructive testing (NDT) of concrete. In this study the pulse com...

متن کامل

Ultrasonic Imaging in Air with a Broadband Inverse Synthetic Aperture Sonar

An experimental ultrasound scanning sonar has been developed that uses a phased ultrasonic transducer array to image objects through the air. The sonar generates arbitrary long duration broadband signals and uses pulse compression to achieve a high range resolution and a high signal to noise ratio. This paper considers using the sonar in an inverse synthetic aperture side-scan configuration, wh...

متن کامل

Fibre-optic probe hydrophone for ultrasonic and shock-wave measurements in water

Aimed at lithotripter acoustic output measurements, a new fibre-optic probe hydrophone overcomes most of the problems involved with the use of piezoelectric hydrophone technology in non-linear ultrasonic and shock-wave fields. The fibre-optic principle allows for extremely wide bandwidth (larger than 1 GHz) and superior electromagnetic shielding. Contrary to hitherto existing hydrophones a high...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the Optical Society of America

دوره 62 5  شماره 

صفحات  -

تاریخ انتشار 1972