Measuring QT dispersion: man versus machine.

نویسندگان

  • A Murray
  • N B McLaughlin
  • R W Campbell
چکیده

OBJECTIVE To compare manual and computer automated techniques for measuring QT dispersion. DESIGN Assessment of the ability of manual and automatic measurements of QT dispersion to discriminate between a normal group and two cardiac groups. SUBJECTS 12 simultaneous electrocardiogram leads were recorded from 25 healthy volunteers, 25 subjects after myocardial infarction, and 25 with cardiac arrhythmias. MAIN OUTCOME MEASURES For each subject, QT dispersion was measured as the difference between the maximum and minimum QT from all 12 leads and separately for only those leads with T amplitudes of > 100 microV and for those > 250 microV. RESULTS Manual QT dispersion (T > 100 microV) was greater (P < 0.02) in the arrhythmia patients (mean (SD), 45 (21) ms), but not the infarction patients (54 (36) ms), than in the normal subjects (39 (13) ms). There were no significant differences when all T waves were included. QT dispersion was significantly reduced by an average of 30% when T waves < 100 microV were excluded, and by 51% when those < 250 microV were excluded. Automatic techniques gave different measurements for dispersion in comparison with manual measurements. Three of the four automatic techniques detected significant differences between normal and both patient groups when no leads were excluded (P < 0.01) as well as when T waves < 100 microV were excluded (with increased significance, P < 0.002). CONCLUSIONS Measurements of QT dispersion from small T waves increases measurement variability and reduces the potential for detecting clinical differences. Automatic measurement of QT dispersion gives different results from manual measurement, but can satisfactorily discriminate between normal and abnormal groups with good quality electrocardiograms.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Tissue magnesium levels and the arrhythmic substrate in humans.

INTRODUCTION Magnesium deficiency has been implicated in the pathogenesis of sudden death, but the investigation of arrhythmic mechanisms has been hindered by difficulties in measuring cellular tissue magnesium stores. METHODS AND RESULTS To see if magnesium deficiency is associated with a propensity toward triggered arrhythmias, we measured tissue magnesium levels and QT interval dispersion ...

متن کامل

Effect of Valsalva Maneuver on QT Dispersion in Hemodialysis Patients.

Increased QT dispersion seems to be related to an increased risk of arrhythmia and sudden death, a common cause of mortality in hemodialysis (HD) patients. Increase in sympathetic tone has been documented in HD patients. In this study, we aimed to investigate the effect of changes in the autonomic tone on QT dispersion (QTd) in HD patients. Twenty HD patients (M/F 13/7; age, mean ±SD, 28 ± 10 y...

متن کامل

QT-Dispersion as a potential marker in prognosis of acute myocardial infarction

Introduction: QT dispersion in a 12 lead ECG represents the heterogeneity of ventricular repolarization. The prolongation of QT-interval dispersion increases the risk of coronary heart disease, ventricular arrhythmia, and sudden cardiac death in patients with myocardial infarction. We aimed to investigate the prognostic value of QT-dispersion in patients with acute myocardial infarction. Meth...

متن کامل

The impact of chronic hemodialysis on QT dispersion corrected QTdispersion and maximum QT-dispersion

Introduction: Sudden cardiac death is common in patients on hemodialysis and may occur in the immediate postdialysis period when ventricular premature complexes are common. QT dispersion reflecting hetovogelity in ventricle repolarization has been used for predicting patients with risk of malignant arrhythmia and sudden death. The purpose of the study was to assess the effect of hemodialysis on...

متن کامل

QT dispersion: an indication of arrhythmia risk in patients with long QT intervals.

Homogeneity of recovery time protects against arrhythmias whereas dispersion of recovery time is arrhythmogenic. A single surface electrocardiographic QT interval gives no information on recovery time dispersion but the difference between the maximum and minimum body surface QT interval may be relevant. This hypothesis was tested by measuring the dispersion of the corrected QT interval (QTc) in...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Heart

دوره 77 6  شماره 

صفحات  -

تاریخ انتشار 1997