Spectral Module for Photon Monte Carlo Calculations in Hypersonic Nonequilibrium Radiation
نویسندگان
چکیده
In this paper, efficient spectral modules and random number databases are developed for atomic and diatomic species for use in photon Monte Carlo (PMC) modeling of hypersonic nonequilibrium flow radiation. To model nonequilibrium flow conditions, the quasisteady state assumption was used to generate electronic state populations of atomic and diatomic gas species in the databases. For atomic species (N and O), both bound-bound transitions and continuum radiation were included and were separately databased as a function of electron temperature and number density as well as the ratio of atomic ion to neutral number density. For the radiating diatomic species of N2 , N2, O2, and NO databases were generated for each electronic molecular electronic system. In each molecular electronic system, the rovibrational transition lines were separately databased for each electronic upper state population forming the electronic system. The spectral module for the PMC method was optimized toward computational efficiency for emission calculations, wavelength selections of photon bundles and absorption coefficient calculations in the ray tracing scheme. DOI: 10.1115/1.4000242
منابع مشابه
Dose Calculations for Lung Inhomogeneity in High-Energy Photon Beams and Small Beamlets: A Comparison between XiO and TiGRT Treatment Planning Systems and MCNPX Monte Carlo Code
Introduction Radiotherapy with small fields is used widely in newly developed techniques. Additionally, dose calculation accuracy of treatment planning systems in small fields plays a crucial role in treatment outcome. In the present study, dose calculation accuracy of two commercial treatment planning systems was evaluated against Monte Carlo method. Materials and Methods Siemens Once or linea...
متن کاملDevelopement a simple point source model for Elekta SL-25 linear accelerator using MCNP4C Monte Carlo code
Background: Monte Carlo (MC) modeling of a linear accelerator is a prerequisite for Monte Carlo dose calculations in external beam radiotherapy. In this study, a simple and efficient model was developed for Elekta SL-25 linear accelerator using MCNP4C Monte Carlo code Materials and methods: The head of Elekta SL-25 linac was simulated for 6 and 18 MV photon beams using MCNP4C MC code. Energ...
متن کاملSmall photon field dosimetry using EBT2 Gafchromic film and Monte Carlo simulation
Background: Small photon fields are increasingly used in modern radiotherapy especially in intensity modulated radiation therapy (IMRT) and stereotactic radiosurgery (SRS) treatments. Accurate beam profile and central axis depth doses measurements of such beams are complicated due to the electron disequilibrium. Hence the EBT2 (external beam therapy) Gafchromic film was used for dosimetry of sm...
متن کاملEvaluation of Iridium_192 radioisotope dosimeter calculations for vascular Brachiotherapy
Introduction: One of the most effective means for treatment of coronary arteries cramp (CHD) is coronary intravascular Brachiotherapy. In this study, with use of MCNP code, in order to invastigating the score of ditribution of absorbed dose, drope in dose, and simulation mean, radiation doses around iridium_192 radioactive has been done. Materials and Methods:</str...
متن کاملComparison of dosimetry parameters of two commercially available Iodine brachytherapy seeds using Monte Carlo calculations
Background: Iodine brachytherapy sources with low photon energies have been widely used in treating cancerous tumors. Dosimetric parameters of brachytherapy sources should be determined according to AAPM TG-43U1 recommendations before clinical use. Monte Carlo codes are reliable tools in calculation of these parameters for brachytherapy sources. Materials and Methods: Dosimetric param...
متن کامل