Evaluation of Heat Transfer to the Implant-Bone Interface During Removal of Metal Copings Cemented onto Titanium Abutments.
نویسندگان
چکیده
PURPOSE The aim of this investigation was to measure the temperature increase due to heat transferred to the implant-bone interface when the abutment screw channel is accessed or a metal-ceramic crown is sectioned buccally with diamond or tungsten carbide bur using an air rotor, with or without irrigation. MATERIALS AND METHODS Cobalt-chromium copings were cemented onto straight titanium abutments. The temperature changes during removal of the copings were recorded over a period of 1 minute. RESULTS The sectioning of coping with diamond bur and without water irrigation generated the highest temperature change at the cervical part of the implant. CONCLUSION Both crown removal methods resulted in an increase in temperature at the implant-bone interface. However, this temperature change did not exceed 47°C, the potentially damaging threshold for bone reported in the literature.
منابع مشابه
Assessment and comparison of retention of zirconia copings luted with different cements onto zirconia and titanium abutments: An in vitro study
AIM The purpose of this in vitro study was to assess and compare the retention of zirconia copings luted with different luting agents onto zirconia and titanium abutments. MATERIALS AND METHODS Titanium and zirconia abutments were torqued at 35 N/cm onto implant analogs. The samples were divided into two groups: Group A consisted of four titanium abutments and 32 zirconia copings and Group B ...
متن کاملResistance to dislodgement of zirconia copings cemented onto titanium abutments of different heights.
STATEMENT OF PROBLEM For patients with limited interocclusal space, standard height implant abutments may not be usable. Shorter abutments may be desirable. PURPOSE The purpose of this study was to determine the effect of the height of titanium abutments on the tensile strength required to dislodge zirconia copings. MATERIAL AND METHODS Two experimental groups of abutments were prepared: (1...
متن کاملEvaluation of the Effect of Zirconia and Titanium Abutments on Microleakage of Implant-Abutment Interface Under Oblique Cyclic Loading In Vitro
Background and Aim: Oral bacteria can proliferate in the implant-abutment interface (IAI) and cause inflammation in the peri-implant tissues and adjacent bone. This study aimed to assess the effect of zirconia and titanium abutments on the microleakage of the IAI under oblique cyclic loading conditions. Materials and Methods: In this in-vitro study, 12 implant-abutment assemblies with zirconia...
متن کاملComparative Evaluation of Microleakage at the Interface of Titanium and Zirconium Abutments Following Oblique Cyclic Loading: An in vitro Study
Abstract Background and aim: Oral microbiota could proliferate the microspace between the implant and abutment, thereby cause inflammation in the peri-implant tissues and adjacent bone. This study aimed to investigate the effect of two types of abutments (zirconia and titanium) on microleakage at implant-abutment interface area under oblique cyclic loading in vitro. Materials and methods:In thi...
متن کاملAbstracts [Bonding Titan_Zirkon] 32012
Two experimental groups of abutments were prepared: (1) 4.3-mm platform width implant abutment with a 6.5-mm height (control), and (2) a 4.3-mm platform width implant abutment with a 5.5-mm height (shorter). Each abutment had 5 zirconia copings (custom designed) fabricated through a 3-dimensional computer-assisted design (3-D CAD) process by scanning an identical wax pattern. The zirconia copin...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The International journal of prosthodontics
دوره 29 3 شماره
صفحات -
تاریخ انتشار 2016