Erratum to: Can calculation of energy expenditure based on CO2 measurements replace indirect calorimetry?

نویسندگان

  • Taku Oshima
  • Séverine Graf
  • Claudia-Paula Heidegger
  • Laurence Genton
  • Jérôme Pugin
  • Claude Pichard
چکیده

BACKGROUND Methods to calculate energy expenditure (EE) based on CO2 measurements (EEVCO2) have been proposed as a surrogate to indirect calorimetry. This study aimed at evaluating whether EEVCO2 could be considered as an alternative to EE measured by indirect calorimetry. METHODS Indirect calorimetry measurements conducted for clinical purposes on 278 mechanically ventilated ICU patients were retrospectively analyzed. EEVCO2 was calculated by a converted Weir's equation using CO2 consumption (VCO2) measured by indirect calorimetry and assumed respiratory quotients (RQ): 0.85 (EEVCO2_0.85) and food quotient (FQ; EEVCO2_FQ). Mean calculated EEVCO2 and measured EE were compared by paired t test. Accuracy of EEVCO2 was evaluated according to the clinically relevant standard of 5% accuracy rate to the measured EE, and the more general standard of 10% accuracy rate. The effects of the timing of measurement (before or after the 7th ICU day) and energy provision rates (<90 or ≥90% of EE) on 5% accuracy rates were also analyzed (chi-square tests). RESULTS Mean biases for EEVCO2_0.85 and EEVCO2_FQ were -21 and -48 kcal/d (p = 0.04 and 0.00, respectively), and 10% accuracy rates were 77.7 and 77.3%, respectively. However, 5% accuracy rates were 46.0 and 46.4%, respectively. Accuracy rates were not affected by the timing of the measurement, or the energy provision rates at the time of measurements. CONCLUSIONS Calculated EE based on CO2 measurement was not sufficiently accurate to consider the results as an alternative to measured EE by indirect calorimetry. Therefore, EE measured by indirect calorimetry remains as the gold standard to guide nutrition therapy.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Data Quality Control and Improvement of Indirect Human Calorimeter by System Dynamics Approach J. Futami &H. Kashiwazaki Data Quality Control and Improvement of Indirect Human Calorimeter by System Dynamics Approach

Using a system dynamics approach, a simulation model for data quality control and improvement of human calorimeter using the indirect calorimetry (IHC: indirect human calorimeter) was constructed. Accurate measurements of human energy expenditure are necessary in estimating appropriate energy requirement. IHC can measure continuously energy expenditure over 24 hours. O2 and CO2 analyzers and fl...

متن کامل

CALL FOR PAPERS Integrative and Translational Physiology: Integrative Aspects of Energy Homeostasis and Metabolic Diseases Indirect calorimetry in laboratory mice and rats: principles, practical considerations, interpretation and perspectives

Even PC, Nadkarni NA. Indirect calorimetry in laboratory mice and rats: principles, practical considerations, interpretation and perspectives. Am J Physiol Regul Integr Comp Physiol 303: R459–R476, 2012. First published June 20, 2012; doi:10.1152/ajpregu.00137.2012.—In this article, we review some fundamentals of indirect calorimetry in mice and rats, and open the discussion on several debated ...

متن کامل

Short Communication Anaerobic Heat Production Measurements: a New Perspective

Heat production measurements can be performed in two ways: direct and indirect calorimetry. Direct calorimetry is the measurement of heat loss, which under normal steady-state conditions equals the heat production (H). Indirect calorimetry is the calculation of heat production based on parameters related to the heat production, such as respiratory gas exchange (O2 and CO2) and nitrogen excretio...

متن کامل

Using Doubly-Labeled Water to Measure Energy Expenditure in an Important Small Ectotherm Drosophila melanogaster

Energy expenditure is a key variable in the study of ageing, and the fruit fly Drosophila melanogaster is a model organism that has been used to make step changes in our understanding of the ageing process. Standard methods for measurement of energy expenditure involve placing individuals in metabolic chambers where their oxygen consumption and CO2 production can be quantified. These measuremen...

متن کامل

Indirect calorimetry in laboratory mice and rats: principles, practical considerations, interpretation and perspectives.

In this article, we review some fundamentals of indirect calorimetry in mice and rats, and open the discussion on several debated aspects of the configuration and tuning of indirect calorimeters. On the particularly contested issue of adjustment of energy expenditure values for body size and body composition, we discuss several of the most used methods and their results when tested on a previou...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 21  شماره 

صفحات  -

تاریخ انتشار 2017