Tidal hyperinflation during low tidal volume ventilation in acute respiratory distress syndrome.
نویسندگان
چکیده
RATIONALE Tidal volume and plateau pressure limitation decreases mortality in acute respiratory distress syndrome. Computed tomography demonstrated a small, normally aerated compartment on the top of poorly aerated and nonaerated compartments that may be hyperinflated by tidal inflation. OBJECTIVES We hypothesized that despite tidal volume and plateau pressure limitation, patients with a larger nonaerated compartment are exposed to tidal hyperinflation of the normally aerated compartment. MEASUREMENTS AND MAIN RESULTS Pulmonary computed tomography at end-expiration and end-inspiration was obtained in 30 patients ventilated with a low tidal volume (6 ml/kg predicted body weight). Cluster analysis identified 20 patients in whom tidal inflation occurred largely in the normally aerated compartment (69.9 +/- 6.9%; "more protected"), and 10 patients in whom tidal inflation occurred largely within the hyperinflated compartments (63.0 +/- 12.7%; "less protected"). The nonaerated compartment was smaller and the normally aerated compartment was larger in the more protected patients than in the less protected patients (p = 0.01). Pulmonary cytokines were lower in the more protected patients than in the less protected patients (p < 0.05). Ventilator-free days were 7 +/- 8 and 1 +/- 2 d in the more protected and less protected patients, respectively (p = 0.01). Plateau pressure ranged between 25 and 26 cm H(2)O in the more protected patients and between 28 and 30 cm H(2)O in the less protected patients (p = 0.006). CONCLUSIONS Limiting tidal volume to 6 ml/kg predicted body weight and plateau pressure to 30 cm H(2)O may not be sufficient in patients characterized by a larger nonaerated compartment.
منابع مشابه
Low Tidal Volume Ventilation in Patients without Acute Respiratory Distress Syndrome: A Paradigm Shift in Mechanical Ventilation
Protective ventilation with low tidal volume has been shown to reduce morbidity and mortality in patients suffering from acute lung injury (ALI) and acute respiratory distress syndrome (ARDS). Low tidal volume ventilation is associated with particular clinical challenges and is therefore often underutilized as a therapeutic option in clinical practice. Despite some potential difficulties, data ...
متن کاملAcute Respiratory Distress Syndrome in a Patient With Suspected Influenza: A Case Report
Acute Respiratory Distress Syndrome (ARDS) is a clinical syndrome consisting of tachypnea, refractory hypoxemia, and diffuse opacities on chest radiographs after infection or trauma which ultimately leads to respiratory failure. The principles of treatment are based on patient care in ICU, mechanical ventilation and medical treatments. By using lower plateau, less tidal volume, higher positive ...
متن کاملFailure of Noninvasive Ventilation for De Novo Acute Hypoxemic Respiratory Failure: Role of Tidal Volume.
OBJECTIVES A low or moderate expired tidal volume can be difficult to achieve during noninvasive ventilation for de novo acute hypoxemic respiratory failure (i.e., not due to exacerbation of chronic lung disease or cardiac failure). We assessed expired tidal volume and its association with noninvasive ventilation outcome. DESIGN Prospective observational study. SETTING Twenty-four bed unive...
متن کاملSmaller Tidal Volumes Improve ARDS Tidal Volume Lower Than 6 mL/kg Enhances Lung Protection: Role of Extracorporeal Carbon Dioxide Removal
Background: ARDSnet data reaffirm the practice of limiting tidal volume in patients with lung injury to 6 to 8 mL/kg of predicted body weight and limiting plateau pressures to avoid additional lung injury and excess mortality. Objective: To determine whether tidal volume <6 mL/kg is protective to the lungs and whether consequent respiratory acidosis can be managed by extracorporeal carbon dioxi...
متن کاملPositive end-expiratory pressure in acute respiratory distress syndrome: should the 'open lung strategy' be replaced by a 'protective lung strategy'?
In patients with acute respiratory distress syndrome, positive end-expiratory pressure is associated with alveolar recruitment and lung hyperinflation despite the administration of a low tidal volume. The best positive end-expiratory pressure should correspond to the best compromise between recruitment and distension, a condition that coincides with the best respiratory elastance.
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Respiratory care
دوره 46 1 شماره
صفحات -
تاریخ انتشار 2001