ChemiCal stability of Ceftriaxone by a validated stability-indiCating liquid ChromatographiC method
نویسندگان
چکیده
The chemical stability of ceftriaxone for injection reconstituted with water was studied at different storage conditions by a validated stability-indicating ion-pair liquid chromatographic method. The study was performed on ceftriaxone for injection samples obtained from two pharmaceutical laboratories, at three different temperatures: 23 oC ± 2 oC, + 8 oC ± 1 oC and 20 oC ± 0.5 oC, over 26 days, 55 days, and 76 days, respectively. Chromatographic separation was achieved on a RP-18 column, using a mobile phase consisting of 250 mL acetonitrile, 50 mL phosphate buffer (pH 7.4; 0.1M), 3.2 g tetrabutylammonium bromide made up to a volume of 1 L with water, at a flow rate of 1.0 mL min−1 and UV detection at 260 nm. The stability-indicating capability of the assay was established by forced degradation studies under hydrolysis, high temperature and photolysis. The developed method was specific, stability indicating, accurate and precise for ceftriaxone determination. At room temperature and at + 8 oC the degradation of ceftriaxone followed first-order kinetics and the samples were chemically stable for at least 4 and 41 days respectively. At 20 oC the concentration of all samples remained higher than 90% of the original concentration. Degradation of ceftriaxone was higher at room temperature; therefore lower storage temperatures improved the chemical stability of ceftriaxone for injection in water.
منابع مشابه
Rapid Analysis of Glibenclamide Using an Environmentally Benign Stability-Indicating RP-HPLC Method
An environmentally benign RP-HPLC approach for rapid analysis of glibenclamide in pure form, developed nanoemulsion and commercial tablets was developed and validated in present investigation. The green chromatographic identification was performed on Lichrosphere 250 X 4.0 mm RP C8 column having a 5µm packing as a stationary phase using a combination of ethanol: methanol (50:50 % v/v) as a mobi...
متن کاملRapid Analysis of Glibenclamide Using an Environmentally Benign Stability-Indicating RP-HPLC Method
An environmentally benign RP-HPLC approach for rapid analysis of glibenclamide in pure form, developed nanoemulsion and commercial tablets was developed and validated in present investigation. The green chromatographic identification was performed on Lichrosphere 250 X 4.0 mm RP C8 column having a 5µm packing as a stationary phase using a combination of ethanol: methanol (50:50 % v/v) as a mobi...
متن کاملDevelopment and validation of a fast, simple and specific stability indicating RP-HPLC method for determination of Dexpanthenol in eye gel formulation.
AIn this study a simple and reliable stability-indicating RP-HPLC method was developed and validated for analysis of Dexpanthenol in an artificial tear formulation. The chromatographic separation was performed on a HPLC C18 column (25.0 cm 4.6 mm, 5 m) using a mixture of 0.037 M monobasic potassium phosphate in water (adjusted with 0.1% (v/v) phosphoric acid to a pH of 3.2) and methanol (90:...
متن کاملDevelopment and validation of a fast, simple and specific stability indicating RP-HPLC method for determination of Dexpanthenol in eye gel formulation.
AIn this study a simple and reliable stability-indicating RP-HPLC method was developed and validated for analysis of Dexpanthenol in an artificial tear formulation. The chromatographic separation was performed on a HPLC C18 column (25.0 cm 4.6 mm, 5 m) using a mixture of 0.037 M monobasic potassium phosphate in water (adjusted with 0.1% (v/v) phosphoric acid to a pH of 3.2) and methanol (90:...
متن کاملA stability-Indicating HPLC Method for Simultaneous Determination of Creatine Phosphate Sodium and its Related Substances in Pharmaceutical Formulation
The objective of the study was to develop a simple, specific and stability-indicating HPLC method for the simultaneous determination of creatine phosphate sodium (CPS) and its related substances in pharmaceutical formulation. Separation of creatine phosphate sodium from its major process impurities and degradation products was achieved on a Hypersil BDS C18 column (250 × 4.6 mm, 5 μm) with an a...
متن کامل