Short-term measurement of catabolic rates using iodine-labeled plasma protein.

نویسندگان

  • A S McFarlane
  • A Koj
چکیده

Fractional catabolic rates of iodine-labeled plasma albumins and fibrinogens have been measured in experiments of a few hours duration in adult rabbits. The method used which is based on release of labeled iodide from the protein gives accurate estimates of catabolic rates (expressed as fractions of the plasma protein pool catabolized per day) after 36 hr without the need for urine collections. At earlier times and using undenatured albumin, fractional catabolic rates increased steadily from approximately 10% per day in the first few hours to a constant 20-25% per day after 24 hr. Fibrinogen values which started at 15% plateaued after 24 hr at 30-35% per day. The fractional synthesis rate of albumin, measured with (14)C-labeled carbonate in the first 6 hr when the short-term fractional catabolic rate was 10.2% agreed with the 36 hr plateau value of 29% per day. The presence of traces of denatured or polymerized proteins was revealed by high initial fractional catabolic rates, and in a few experiments biological screening in another animal was not fully effective in removing them. On the other hand, some labeled albumins showed no traces of denatured protein even without biological screening. Fibrinogen polymer was catabolized rapidly and behaved like denatured or incipiently clotted fibrinogen. Irradiation of albumin produced a marked increase in early fractional catabolic rates, and some proteins after prolonged storage and labeling behaved similarly. Alternative theories to explain the low fractional catabolic rates in the first 24 hr are considered. Since radioautographic experiments failed to provide evidence for retention of labeled proteins or their nondiffusible breakdown products inside catabolic cells, preference is given to the view that catabolism occurs in a pool of significant protein content which is either a subunit of the extravascular pool or is independent and sandwiched between the plasma and extravascular pools. Earlier hypotheses concerning small catabolic pools in which protein specific activities approximate closely to plasma values at the same time are considered to be no longer tenable.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Use of 125-I- and 51-Cr-labeled albumin for the measurement of gastrointestinal and total albumin catabolism.

A method for the simultaneous measurement of gastrointestinal protein loss and total albumin turnover entailing the use of a combination of (125)iodine- and (51)chromium-labeled albumin is described. Albumin turnover was calculated by the measurement of albumin-(125)I plasma decay and cumulative urinary excretion, and the results obtained agreed closely with previous studies utilizing albumin-(...

متن کامل

Short-term effectiveness of mandatory iodization of table salt, at an elevated iodine concentration, on the iodine and goiter status of schoolchildren with endemic goiter.

BACKGROUND Goiter rates and iodine deficiency usually show marked improvement in efficacy studies of mandatory iodization of salt, but little is known about the short-term effectiveness of mandatory iodization. OBJECTIVE The aim of the study was to evaluate, after 1 y, the effectiveness of mandatory iodization of salt at an iodine concentration higher than that occurring under optional iodiza...

متن کامل

Direct measurement of the rates of synthesis of plasma proteins in control subjects and patients with gastrointestinal protein loss.

The guanido carbon of hepatic arginine is the common precursor of urea and of the arginine of plasma proteins synthesized in the liver. It is possible to measure the momentary synthetic rates of plasma proteins by "pulse labeling" this arginine pool with bicarbonate-(14)C. In the current study, this method has been adapted in order to use urinary urea data and was applied to control subjects an...

متن کامل

Measurement of the Radiation Dose Rates of Patients Receiving Treatment with I-131 Using Telescopic Radiation Survey Meter

Introduction In order to discharge the patients receiving treatment with large radiation doses of 131I for thyroid cancer, it is necessary to measure and evaluate the external dose rates of these patients. The aim of the study was to assess a new method of external dose rate measurement, and to analyze the obtained results as a function of time. Materials and Methods In this study, a telescopic...

متن کامل

Designing a Radioimmunometric Assay Kit for Prostate-Specific Antigen Measurement Using Polystyrene Tubes Coated By Immunochemical Method

ABSTRACT        Background and Objective: Prostate specific antigen (PSA) is considered as one of the most reliable biomarkers of cancer and other known prostate diseases. In the present study, solid phase sandwich immunoradiometric assay was used to measure the amount of PSA. In this type of measurement, a pair of anti-PSA antibodies on the solid phase and la...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of clinical investigation

دوره 49 10  شماره 

صفحات  -

تاریخ انتشار 1970