Peak height pattern in dichloro-rhodamine and energy transfer dye terminator sequencing.

نویسندگان

  • H Zakeri
  • G Amparo
  • S M Chen
  • S Spurgeon
  • P Y Kwok
چکیده

Establishing the pattern in peak heights within local sequence contexts improves the accuracy of base calling and the identification of DNA sequence variations in dye-terminator cycle sequencing. We have systematically examined pairs of sequence-tagged sites (STSs) that vary at only a single nucleotide to determine how base changes influence the peak heights of neighboring bases in sequencing traces generated by two recently commercialized dye-terminator chemistries, the dichloro-rhodamine (dRhodamine) and the energy transfer (BigDye) terminators. For sequencing traces generated with the dRhodamine terminators, the peak height of a particular base in 28 of 64 possible 3-base windows (44%) can be predicted by knowing just one or two bases 5' to the base in question. For those generated with the BigDye terminators, the peak height of a particular base in 23 of 64 possible 3-base windows (36%) can be predicted by knowing the local sequence context. When the peak heights are binned slightly differently, 75% (48 out of 64 cases) of the base peaks generated by both dRhodamine and BigDye terminators fall in the middle half, confirming that the peak patterns of these two new dye terminator chemistries are much more even than those found in the original rhodamine dye terminator sequences.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

AmpliTaq DNA polymerase, FS dye-terminator sequencing: analysis of peak height patterns.

Taq DNA polymerases in which the phenylalanine is substituted by a tyrosine at position 667 (Taq F667Y) are members of a new class of DNA polymerases that incorporate chain-terminating dideoxyribonucleoside triphosphates (ddNTPs) much more efficiently than the wild-type Taq DNA polymerase. Improved incorporation of ddNTPs into DNA during cycle sequencing using AmpliTaq DNA polymerase, FS (Taq-F...

متن کامل

New energy transfer dyes for DNA sequencing.

We have synthesized a set of four energy transfer dyes and demonstrated their use in automated DNA sequencing. The donor dyes are the 5- or 6-carboxy isomers of 4'-aminomethylfluorescein and the acceptor dyes are a novel set of four 4,7-dichloro-substituted rhodamine dyes which have narrower emission spectra than the standard, unsubstituted rhodamines. A rigid amino acid linker, 4-aminomethylbe...

متن کامل

Increased maternal plasma fetal DNA concentrations in women who eventually develop preeclampsia.

was Ampli-Taq DNA polymer-ase. Another problem may be attributable to the production of uneven peak-height patterns, which are caused by differences in the efficiency of dideoxy termination at different bases and are affected by sequence context as well. Zakeri et al. (5) reported that a heterozygous C peak was much smaller in size than a heterozygous G peak. This is in agreement with our resul...

متن کامل

Design strategies and performance of custom DNA sequencing primers.

This study surveyed strategies of sequencing primer selection and evaluated primer performance in automated DNA sequencing. We asked participants to relate their preferred primer design strategies to identify primer characteristics that are considered most important in sequencing primer design. The participants preferred primers of 18-24 nucleotides (nt), 39%-58% G + C, a melting temperature (T...

متن کامل

Manganese citrate improves base-calling accuracy in DNA sequencing reactions using rhodamine-based fluorescent dye-terminators.

While dideoxy-terminators labeled with rhodamine-based fluorescent dyes provide the most versatile method of automated DNA sequencing, variation in peak heights reduces base-calling accuracy. We describe a simple approach that uses additions of a manganese salt and the metal buffer sodium citrate (MnCit) to overcome this limitation. This modification reduces peak height variability >2-fold and ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • BioTechniques

دوره 25 3  شماره 

صفحات  -

تاریخ انتشار 1998