Options to Expand HIV Viral Load Testing in South Africa: Evaluation of the GeneXpert® HIV-1 Viral Load Assay
نویسندگان
چکیده
BACKGROUND Expansion of HIV viral load (VL) testing services are required to meet increased targets for monitoring patients on antiretroviral treatment. South Africa currently tests >4million VLs per annum in 16 highly centralised, automated high-throughput laboratories. The Xpert HIV-1 VL assay (Cepheid) was evaluated against in-country predicates, the Roche Cobas Taqmanv2 and Abbott HIV-1RT, to investigate options for expanding VL testing using GeneXpert's random access, polyvalent capabilities and already established footprint in South Africa with the Xpert MTB/RIF assay (207 sites). Additionally, the performance of Xpert HIV-1VL on alternative, off-label specimen types, Dried Blood Spots (DBS) and whole blood, was investigated. METHOD Precision, accuracy (agreement) and clinical misclassification (1000cp/ml) of Xpert HIV-1VL plasma was compared to Taqmanv2 (n = 155) and Abbott HIV-1 RT (n = 145). Misclassification of Xpert HIV-1VL was further tested on DBS (n = 145) and whole blood (n = 147). RESULTS Xpert HIV-1VL demonstrated 100% concordance with predicate platforms on a standardised frozen, plasma panel (n = 42) and low overall percentage similarity CV of 1.5% and 0.9% compared to Taqmanv2 and Abbott HIV-1 RT, respectively. On paired plasma clinical specimens, Xpert HIV-1VL had low bias (SD 0.32-0.37logcp/ml) and 3% misclassification at the 1000cp/ml threshold compared to Taqmanv2 (fresh) and Abbott HIV-1 RT (frozen), respectively. Xpert HIV-1VL on whole blood and DBS increased misclassification (upward) by up to 14% with increased invalid rate. All specimen testing was easy to perform and compatible with concurrent Xpert MTB/RIF Tuberculosis testing on the same instrument. CONCLUSION The Xpert HIV-1VL on plasma can be used interchangeably with existing predicate platforms in South Africa. Whole blood and DBS testing requires further investigation, but polyvalency of the GeneXpert offers a solution to extending VL testing services.
منابع مشابه
Evaluation of the Abbott m2000 RealTime human immunodeficiency virus type 1 (HIV-1) assay for HIV load monitoring in South Africa compared to the Roche Cobas AmpliPrep-Cobas Amplicor, Roche Cobas AmpliPrep-Cobas TaqMan HIV-1, and BioMerieux NucliSENS EasyQ HIV-1 assays.
The implementation of antiretroviral therapy demands the need for increased access to viral load (VL) monitoring. Newer real-time VL testing technologies are faster and have larger dynamic ranges and fully automated extraction to benefit higher throughputs in resource-poor environments. The Abbott RealTime human immunodeficiency virus type 1 (HIV-1) assay was evaluated as a new option for testi...
متن کاملNo Evidence for Human Papillomavirus in Patients with HIV in Iran
Background: Human Papillomaviruses (HPVs) have anestablished role in the development of cervical cancer. However, the presence of underlying conditions such as HIV/AIDS is necessary for this to occur. This studyaimed to evaluate the prevalence of HPV DNA in plasma samples from HIV-positive patients in Tehran, Iran. Methods: Plasma specimens from 95 patients diagnosed with HIV infection from Te...
متن کاملAssessment of HTLV-I proviral load, HIV viral load and CD4 T cell count in infected subjects; with an emphasis on viral replication in co-infection
Objective(s): HTLV-I and HIV virus quantification is an important marker for assessment of virus activities. Since there is a direct relationship between the number of virus and disease progression, HTLV- I and HIV co-infection might have an influence on the development of viral associated diseases, thus, viral replication of these viruses and co-infection were evaluated. Materials and...
متن کاملGeneXpert HIV-1 quant assay, a new tool for scale up of viral load monitoring in the success of ART programme in India
BACKGROUND Recent WHO guidelines identify virologic monitoring for diagnosing and confirming ART failure. In view of this, validation and scale up of point of care viral load technologies is essential in resource limited settings. METHODS A systematic validation of the GeneXpert® HIV-1 Quant assay (a point-of-care technology) in view of scaling up HIV-1 viral load in India to monitor the succ...
متن کاملEvaluation of relationship between the level of inflammatory cytokines Interleukin-10 and tumor necrosis factor-alpha with virologic response to treatment in patients with HIV
Background: Despite the considerable advances in acquired immunodeficiency syndrome (AIDS) treatment and management, finding the cure for this disease has been hindered by emerging challenges such as virus resistance and treatment failures. The purpose of this study is to compare the cytokine profiles of patients with successful treatment and patients with unsuccessful treatment to gain a bette...
متن کامل