Forearm extravasation injury during robot-assisted low anterior resection

نویسندگان

  • Ji Hyun Kim
  • Sung Sik Park
  • Jong Chan Kim
  • Jun-Mo Park
  • Sung-Hye Byun
چکیده

provided the original work is properly cited. CC A 47-year-old female with an American Society of Anesthesiologists physical status of I was scheduled for robot-assisted low anterior resection and right hepatectomy. Her routine preoperative examination results were unremarkable. Standard monitoring devices were applied in the operating room, including a noninvasive blood pressure monitoring system, electrocardiogram, and pulse oximeter. A warm blanket was placed under the patient to maintain her body temperature. General anesthesia was induced with propofol 120 mg, continuous remifentanil infusion 0.25 μg/kg/min, and rocuronium 0.6 mg/kg via a pre-existing 20-gauge intravenous catheter in the right ventral forearm without apparent resistance. Anesthesia was maintained with desflurane (5–7 vol%) and remifentanil (0.05–0.20 μg/kg/min). The right radial artery and right subclavian vein were catheterized. The patient was placed into the lithotomy and Trendelenburg position with both arms tucked using a fabric arm-straining device placed immediately proximal to the peripheral cannulation. All cannulations were confirmed to be functional. All fluids and medication were administered through the central cannulation with the exception of the anesthetic induction agents, 1.5 L of crystalloid solution (Plasmalyte A; Baxter, Deerfield, IL, USA), and 250 ml of 5% albumin, the latter two of which are isotonic and iso-oncotic, respectively, with human plasma. Four hours later, both the arterial pressure waveform and the ipsilateral pulse oximeter reading were dampened. The monitoring devices and peripheral line flow were checked, and the peripheral line was not flowing smoothly. Because the intravenous line worked well initially and only malfunctioned later, we assumed that frequent changes in positioning might have affected the alignment or tightness of the catheter and arm-restraining device, potentially kinking or dislodging the catheter. Considering that the operation was almost completed, we immediately stopped using the peripheral intravenous line to prevent extravasation injury. A new pulse oximeter probe was applied to the patient’s right ear. Because the dampening of the arterial cannulation appeared to worsen, noninvasive blood pressure was measured on the opposite arm. At the end of the procedure, the right forearm was undraped. The ventral surface of the arm was mildly swollen with bullae, redness, and skin abrasions, especially under the site of the arm-restraining device (Fig. 1). In contrast, the dorsal surface showed no abnormalities. Physical examination revealed palpable radial arterial capillary filling pressure with no sensory or motor defects. Following consulta-

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Colon Stricture After Ischemia Following a Robot-Assisted Ultra-Low Anterior Resection With Coloanal Anastomosis

Four consecutive cases of a colonic stricture following a da Vinci robot-assisted ultra-low anterior resection (LAR) with coloanal anastomosis and diverting ileostomy for the treatment of rectal cancer are reported. The colonic strictures developed after early proximal colonic ischemia without anastomotic site leakage or disruption. All patients were treated with preoperative chemoradiation the...

متن کامل

Simultaneous robotic low anterior resection and prostatectomy for adenocarcinoma of rectum and prostate: initial case report

BACKGROUND We report a case of synchronous rectal and prostate cancer treated successfully with simultaneous da Vinci robotic-assisted low anterior resection of the rectum and robotic-assisted laparoscopic radical prostatectomy to address both cancers. CASE PRESENTATION Recently, minimally invasive surgical techniques using da Vinci robot® system (Intuitive Surgical, Sunnyvale, USA) were intr...

متن کامل

Comparison of the Rate of Nerve Injury after Posterior and Anterior Approaches in Fractures of Proximal Half of Radius in Adults

This clinical study was carried out to compare the rate of nerve complications after anterior and posterior approaches in forearm both bone fractures in adults. For this purpose, 310 patients with forearm both bone fractures operated during 1997-2002 in Kerman Shahid Bahonar Hospital were studied. From these patients, 121 cases werefemale and 189 cases were male and they were aged from 12 to 67...

متن کامل

Anastomotic leak after low anterior resection: a spectrum of clinical entities.

IMPORTANCE Anastomotic leak is a potentially devastating complication of bowel surgery, yet a leak can refer to a range of clinical problems, with disparate treatment and outcomes. OBJECTIVES To qualitatively categorize the spectrum of anastomotic leaks that occur after low anterior resection for rectal cancer and to describe their effect on outcomes. DESIGN AND SETTING Retrospective review...

متن کامل

Median nerve neuropathy in the forearm due to recurrence of anterior wrist ganglion that originates from the scaphotrapezial joint: Case Report

BACKGROUND Median nerve neuropathy caused by compression from a tumor in the forearm is rare. Cases with anterior wrist ganglion have high recurrence rates despite surgical treatment. Here, we report the recurrence of an anterior wrist ganglion that originated from the Scaphotrapezial joint due to incomplete resection and that caused median nerve neuropathy in the distal forearm. CASE PRESENT...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 67  شماره 

صفحات  -

تاریخ انتشار 2014