Long-term Follow-up (Minimum 5 Years) Study of Single-level Posterior Dynamic Stabilization in Lumbar Degenerative Disease; 'Interspinous U' & 'DIAM'

نویسندگان

  • Yeon Joon Kim
  • Sang Gu Lee
  • Chan Woo Park
  • Seong Son
  • Woo Kyung Kim
چکیده

OBJECTIVES Recently posterior dynamic stabilizations (PDS) are increased in degenerative lumbar disease. But, some previous studies had doubts its long term prognosis. Long term clinical and radiological results of PDS using interspinous device (Interspinous U, DIAM) were analyzed. METHODS We have used the 'interspinous U' and 'DIAM' for patients with lumbar spinal stenosis. We included single level lumbar spinal stenosis patients who completed minimum 60 months follow-up evaluation. All patients checked plain lateral and flexion-extension views at immediately after the surgery and each follow-up. The clinical outcome was measured by Odom's criteria. Complications including post operative infection, bony erosion, device fracture, device malformations, and instabilities were surveyed. RESULTS We included 18 for 'Interspinous U' and 7 patients 'DIAM' groups. Mean follow-up durations for 'Interspinous U' and 'DIAM' were 74.6 and 62.6 months, respectively. Satisfactory groups were 50.0% and 42.9 % for 'Interspinous U' and 'DIAM' groups. In 'Interspinous U' group disc height ratio increased transiently in immediate postoperative period (from 0.18 to 0.21) and then, decreased significantly in last follow-up (0.18). In 'DIAM' group, disc height ratio increased transiently in immediate postoperative period (from 0.18 to 0.19), and then decreased significantly in the last follow-up (0.16). Three (16.7%) and two (28.6%) patients undergo on a re-operation due to severe back pain in 'Interspinous U' and 'DIAM' groups. CONCLUSION Long term follow up 'Interspinous U' and 'DIAM' group showed low patient satisfaction and poor radiological outcomes. To ascertain the benefit of PDS compare with posterior screw fixation, prospective analysis with larger population and multi-center study will be needed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Experience with the second-generation Wallis interspinous dynamic stabilization device implanted in degenerative lumbar disease: a case series of 50 patients.

AIM This study aimed to evaluate the short- to medium-term outcomes of the second-generation Wallis interspinous dynamic stabilization device for treatment of lumbar degenerative disease. MATERIAL AND METHODS Fifty patients with lumbar degenerative disease treated from August 2007 to September 2009 were included in this retrospective study. The Japanese Orthopedic Association (JOA) score and ...

متن کامل

Bone resorption during the first year after implantation of a single-segment dynamic interspinous stabilization device and its risk factors

BACKGROUND Dynamic interspinous stabilization devices generally provide satisfactory results, but can result in recurrent lumbar disc herniation, spinous process fracture, or bone resorption of the spinous process. The purpose of this study was to investigate if the Wallis dynamic stabilization device is associated with bone resorption. METHODS Patients who underwent single-segment posterior ...

متن کامل

Surgical treatment of lumbar spinal stenosis with microdecompression and interspinous distraction device insertion. A case series

BACKGROUND Interspinous distraction devices (IPDD) are indicated as stand-alone devices for the treatment of spinal stenosis. The purpose of this study is to evaluate the results of patients undergoing surgery for spinal stenosis with a combination of unilateral microdecompression and interspinous distraction device insertion. METHODS This is a prospective clinical and radiological study of m...

متن کامل

The Interspinous Spacer: A New Posterior Dynamic Stabilization Concept for Prevention of Adjacent Segment Disease

Introduction. Posterior Dynamic stabilization using the interspinous spacer device is a known to be used as an alternative to rigid fusion in neurogenic claudication patients in the absence of macro instability. Actually, it plays an important in the management of adjacent segment disease in previously fused lumbar spine. Materials and Method. We report our experience with posterior dynamic sta...

متن کامل

Evaluation of a Hybrid Dynamic Stabilization and Fusion System in the Lumbar Spine: A 10 Year Experience

INTRODUCTION The development of adjacent-segment disease is a recognized consequence of lumbar fusion surgery. Posterior dynamic stabilization, or motion preservation, techniques have been developed which theoretically decrease stress on adjacent segments following fusion. This study presents the experience of using a hybrid dynamic stabilization and fusion construct for degenerative lumbar spi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2012