Use of inductively coupled plasma-mass spectrometry in boron-10 stable isotope experiments with plants, rats, and humans.

نویسندگان

  • R A Vanderpool
  • D Hoff
  • P E Johnson
چکیده

The commercial availability of inductively coupled plasma-mass spectrometry technology (ICP-MS) has presented the opportunity to measure the boron concentrations and isotope ratios in a large number of samples with minimal sample preparation. A typical analytical sequence for fecal samples consists of 25 acid blanks, 1 digestion blank, 5 calibration solutions, 4 standard reference material solutions, 10 samples, and 4 natural abundance bias standards. Boron detection limits (3 x 1 sigma) for acid blanks are 0.11 ppb for 10B, and 0.40 ppb for 11B. Isotope ratios were measured in fecal samples with 20 to 50 ppb boron with < 2% relative standard deviation. Rapid washout and minimal memory effects were observed for a 50 ppb beryllium internal standard, but a 200 ppb boron biological sample had a 1.0 ppb boron memory after a 6-min washout. Boron isotope ratios in geological materials are highly variable; apparently this variability is reflected in plants of a fixed natural abundance value for boron requires that a natural abundance ratio be determined for each sample or related data set. The natural abundance variability also prevents quantitation and calculation of isotope dilution by instrument-supplied software. To measure boron transport in animal systems, 20 micrograms of 10B were fed to a fasted rat. During the 3 days after a 10B oral dose, 95% of the 10B was recovered from the urine and 4% from the feces. Urinary isotope ratios, 11B/10B, changed from a natural abundance of 4.1140 to an enriched value of 0.95077, a 77% change.(ABSTRACT TRUNCATED AT 250 WORDS)

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of 137Ba Isotope Abundances in Water Samples by Inductively Coupled Plasma-optical Emission Spectrometry Combined with Least-squares Support Vector Machine Regression

A simple and rapid method for the determination of 137Ba isotope abundances in water samples by inductively coupled plasma-optical emission spectrometry (ICP-OES) coupled with least-squares support vector machine regression (LS-SVM) is reported. By evaluation of emission lines of barium, it was found that the emission line at 493.408 nm provides the best results for the determination...

متن کامل

Novel Applications of Trace Metal Stable Isotope Measurements in Medical Research

The use of multiple-collector inductively coupled plasma mass spectrometry (MC-ICP-MS) for trace metal stable isotope analysis is well established within geochemistry, essentially since the conception of such instruments. The utilization of this high precision technique in medical and life science research has only just begun, however, and the scope of applications is vast, from diagnosis to me...

متن کامل

ICP-MS Measurement of 11B/10B Isotope Ratios in Grapevine Leaves and the Investigation of Possible Boron Isotope Fractionation in Grapevine Plants

S. Afr. J. Enol. Vitic., Vol. 32, No. 1, 2011 *Corresponding author: [email protected] [Tel: +27 (0)11 5592558; Fax: +27 (0)11 5592819] Acknowledgements: The authors thank Winetech (Project No. WW08/28), for research funding, Dr O. Augustyn (ARC-Nietvoorbij, Stellenbosch), for sourcing and collecting wine samples, and Prof C.S. Whitehead and M. Fourie (Department of Botany and Plant Biotechnol...

متن کامل

Study of magnesium bioavailability using stable isotopes and the inductively-coupled plasma mass spectrometry technique in the rat: single and double labelling approaches.

The present work aimed to investigate the feasibility of using stable isotopes and inductively-coupled plasma mass spectrometry (ICP/MS) to study Mg absorption in rats. Male Wistar rats, aged 7 weeks and weighing 180 g, were used. They were fed on a semi-purified diet containing 1070 mg Mg/kg, and had free access to feed and distilled water. In the first experiment, after a 16 d adaptation peri...

متن کامل

Determination of Trace Amounts of Antimony and Boron in High-Purity Iron and Steel by Isotope Dilution/Inductively Coupled Plasma Mass Spectrometry

The highly sensitive and precise determination method for trace amounts of Sb and B in high-purity iron and steel has been established by the isotope dilution/Inductively coupled plasma mass spectrometry. For the determination of Sb, the iron matrix was separated by anion-exchange chromatography using Dowex I-X8 in hydrofluoric acid solution, and the isotope ratio (121Sb/123Sb) of the HNO3/H2O2...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Environmental Health Perspectives

دوره 102  شماره 

صفحات  -

تاریخ انتشار 1994