Higher order aberrations using the NIDEK OPD-Scan and AMO WaveScan.
نویسندگان
چکیده
PURPOSE To compare higher order aberrations measured with the NIDEK OPD-Scan and AMO WaveScan. METHODS Third- to sixth-order higher order aberrations were measured in 1072 eyes using the OPD-Scan and WaveScan. Means, standard deviations, confidence intervals, limits of agreement, and intraclass correlation coefficients (ICC) were calculated. RESULTS Aberrations of greatest magnitude with the OPD-Scan were Z-³/₃ (-0.113 +/- 0.243 μm), Z⁰/₄ (0.073 +/- 0.137 μm), and Z-¹/₃(-0.058 +/- 0.165 μm), and with the WaveScan, 7-³/₃ (-0.054 +/- 0.103 μm), Z⁰/₄ (0.049 +/- 0.083 μm), and Z¹/₃ (-0.017 +/- 0.100 μm). The largest difference in magnitude between the two aberrometers was with Zernike polynomial Z-³/₃ (-0.060 +/- 0.205 μm). Medium consistency (0.6 < ICC < 0.8) was found between the two instruments for Z-¹/₃ and Z⁰/₄. All other Zernike polynomials had a poor consistency (ICC < 0.6) including the total root-mean-square (RMS) higher order aberrations. CONCLUSIONS Poor consistency was found for all aberrations except Z-¹/₃and Z⁰/₄, which demostrated medium consistency. Expected aberration reference values are reported for both instruments.
منابع مشابه
Comparison of the VISX wavescan and OPD-scan III with the subjective refraction.
OBJECTIVE To compare the refractive errors measured by the VISX WaveScan, OPD-Scan III and the subjective refraction. The optometry accuracy of computer operated aberrometer used before refractive surgery has been debatable. Hence, a clear study on the role of such automated equipment in optometry is the need of the hour as compared to subjective refraction. PATIENTS AND METHODS Seventy-six p...
متن کاملPrecision of NIDEK OPD-scan measurements.
PURPOSE To evaluate the repeatability of wavefront measurements using the NIDEK OPD-Scan. METHODS A total of 179 eyes from 90 healthy volunteers (57 women and 33 men) with no corneal or lenticular pathology and normal visual acuity were enrolled in this study. Mean patient age was 39 years (range: 17 to 85 years). All patients underwent four consecutive measurements by one examiner with the N...
متن کاملThe use of NIDEK OPD Scan II wavefront aberrometry in toric intraocular lens implantation.
PURPOSE To present case examples outlining the use of wavefront aberrometry for toric intraocular lens (IOL) implantation pre- and postoperatively. METHODS Twelve eyes that underwent AcrySof Toric IOL (Alcon Inc Laboratories) implantation were assessed pre- and postoperatively using the NIDEK OPD Scan II (NIDEK Co Ltd). Wavefront aberrometry, corneal topography, and objective visual quality w...
متن کاملComparing the effect of two different intraocular lenses on optical aberrations in bilaterally operated eyes for cataract
OBJECTIVE To assess high order and spherical aberrations results of hydrophobic acrylic AMO Sensar AR40E and hydrophobic acrylic Alcon AcrySof SA60AT intraocular lenses after implantation in cases with bilateral cataract. METHODS Cases diagnosed as bilateral cataract were included in the study and preoperative aberration measurements were recorded by using Nidek OPD SCAN-ARK 1000. Groups were...
متن کاملInterpretation of aberrometry measurements in cataract surgery.
PURPOSE To discuss the use of wavefront measurements generated from the NIDEK OPD-Scan II and OPD-Station for cataract surgery. METHODS Case examples are presented along with information and relevant clinical data obtained from the OPD-Scan II aberrometer and OPD-Station software. All eyes underwent corneal topography, wavefront aberrometry, autorefraction, keratometry, and pupillometry measu...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of refractive surgery
دوره 26 8 شماره
صفحات -
تاریخ انتشار 2010