Computed tomography-based evaluation of aortic annulus, prosthesis size and impact on early residual aortic regurgitation after transcatheter aortic valve implantation.
نویسندگان
چکیده
OBJECTIVES Computed tomography (CT) is an increasingly utilized method for the evaluation of patient suitability for transcatheter aortic valve implantation (TAVI). The aim of this study was to analyse the role of CT in the choice of prosthesis and the prevention of residual aortic regurgitation (RAR). METHODS From November 2007 to September 2010, 115 patients (median age 81 years, inter-quantile range (IQR) 76-85; median ejection fraction 55%, IQR 45-60; median logistic EuroSCORE 19.7, IQR 11.0-32.1) undergoing TAVI were evaluated with a pre-procedural CT. An aortic complex was evaluated with multi-planar reconstructions, and we defined significant early RAR as RAR ≥ 2, and prosthesis/annulus mismatch (PAM) as the ratio between prosthesis size and mean annular size. All analyses were conducted for the whole sample and then separately for the two types of prosthesis implanted. RESULTS An Edwards-SAPIEN(®) prosthesis was implanted in 62 patients (54.7%), and a Medtronic CoreValve(®) in 52 (45.2%). Aortic annulus minimum and maximum diameters were 22.6 ± 2.1 and 26.0 ± 2.3 mm, respectively. The aortic annulus diameter and the length of the free edge of the aortic cusps were linearly related to a 1:1 ratio (P < 0.0001). Significant RAR (34 patients, 30%) appeared directly related to the annulus diameters (particularly maximum and medium diameters, P = 0.0003 and P = 0.0010, respectively) and cusp length (P = 0.0007) but inversely correlated with PAM (P = 0.0006). Prosthesis/annulus oversizing was associated with a reduction in RAR, with a cut-off of 7% as the limit below which RAR increases; moreover, we observed different cut-off values for the Edwards and CoreValve prostheses, although statistical significance was not reached for the CoreValve (respectively, 2% with P < 0.0001, 11% with P = 0.16). No association was found between PAM and possible PAM-related complications. CONCLUSIONS CT evaluation prior to TAVI showed that RAR was directly correlated with aortic root dimensions (particularly maximum and medium annulus diameters and cusp lengths) and inversely correlated with PAM. Oversizing the prosthesis by at least 7% reduces the risk of RAR. CT is an essential and invaluable tool in the assessment of patients undergoing TAVI.
منابع مشابه
Is time of renal hypoperfusion an important variable in determining response to renal artery revascularization?
3. Gurvitch R, Webb JG, Yuan R, et al. Aortic annulus diameter determination by multidetector computed tomography: reproducibility, applicability, and implications for transcatheter aortic valve implantation. J Am Coll Cardiol Intv 2011;4:1235–45. 4. Achenbach S, Delgado V, Hausleiter J, Schoenhagen P, Min JK, Leipsic JA. SCCT expert consensus document on computed tomography imaging before tran...
متن کاملTranscatheter aortic valve implantation: role of multi-detector row computed tomography to evaluate prosthesis positioning and deployment in relation to valve function.
AIMS Aortic regurgitation after transcatheter aortic valve implantation (TAVI) is one of the most frequent complications. However, the underlying mechanisms of this complication remain unclear. The present evaluation studied the anatomic and morphological features of the aortic valve annulus that may predict aortic regurgitation after TAVI. METHODS AND RESULTS In 53 patients with severe aorti...
متن کاملSCCT expert consensus document on computed tomography imaging before transcatheter aortic valve implantation (TAVI)/transcatheter aortic valve replacement (TAVR).
Computed tomography (CT) plays an important role in the workup of patients who are candidates for implantation of a catheter-based aortic valve, a procedure referred to as transcatheter aortic valve implantation (TAVI) or transcatheter aortic valve replacement (TAVR). Contrast-enhanced CT imaging provides information on the suitability of the peripheral access vessels to accommodate the relativ...
متن کاملMultidetector row computed tomography parameters associated with paravalvular regurgitation after transcatheter aortic valve implantation.
Multidetector row computed tomographic (MDCT) assessment of aortic annulus dimensions and frame position and deployment have been associated with paravalvular aortic regurgitation (PAVR) after transcatheter aortic valve implantation (TAVI). The present evaluation investigated the (pre- and postprocedure) MDCT associates of PAVR ≥2+. In total, 123 patients referred for TAVI underwent clinical ev...
متن کاملEvaluation and management of paravalvular aortic regurgitation after transcatheter aortic valve replacement.
Paravalvular aortic regurgitation (PAR) negatively affects the prognosis after transcatheter aortic valve replacement (TAVR) with dramatically increased morbidity and mortality in patients with more than mild PAR. Because transcatheter heart valves are implanted in a sutureless fashion using oversizing to anchor the prosthesis stent frame at the level of the virtual aortic annulus, stent frame ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery
دوره 43 1 شماره
صفحات -
تاریخ انتشار 2013