4π noncoplanar stereotactic body radiation therapy for head-and-neck cancer: potential to improve tumor control and late toxicity.
نویسندگان
چکیده
PURPOSE To evaluate the potential benefit of 4π radiation therapy in recurrent, locally advanced, or metastatic head-and-neck cancer treated with stereotactic body radiation therapy (SBRT). METHODS AND MATERIALS Twenty-seven patients with 29 tumors who were treated using SBRT were included. In recurrent disease (n=26), SBRT was delivered with a median 44 Gy (range, 35-44 Gy) in 5 fractions. Three patients with sinonasal mucosal melanoma, metastatic breast cancer, and primary undifferentiated carcinoma received 35 Gy, 22.5 Gy, and 40 Gy in 5 fractions, respectively. Novel 4π treatment plans were created for each patient to meet the objective that 95% of the planning target volume was covered by 100% of the prescription dose. Doses to organs at risk (OARs) and 50% dose spillage volumes were compared against the delivered clinical SBRT plans. Local control (LC), late toxicity, tumor control probability (TCP), and normal tissue complication probability were determined. RESULTS Using 4π plans, mean/maximum doses to all OARs were reduced by 22% to 89%/10% to 86%. With 4π plans, the 50% dose spillage volume was decreased by 33%. Planning target volume prescription dose escalation by 10 Gy and 20 Gy were achieved while keeping doses to OARs significantly improved or unchanged from clinical plans, except for the carotid artery maximum dose at 20-Gy escalation. At a median follow-up of 10 months (range, 1-41 months), crude LC was 52%. The 2-year LC of 39.2% approximated the predicted mean TCP of 42.2%, which increased to 45.9% with 4π plans. For 10-Gy and 20-Gy dose escalation, 4π plans increased TCP from 80.1% and 88.1% to 85.5% and 91.4%, respectively. The 7.4% rate of grade ≥3 late toxicity was comparable to the predicted 5.6% mean normal tissue complication probability for OARs, which was significantly reduced by 4π planning at the prescribed and escalated doses. CONCLUSIONS 4π plans may allow dose escalation with significant and consistent improvements in critical organ sparing, tumor control, and coverage.
منابع مشابه
4π noncoplanar stereotactic body radiation therapy for centrally located or larger lung tumors.
PURPOSE To investigate the dosimetric improvements in stereotactic body radiation therapy for patients with larger or central lung tumors using a highly noncoplanar 4π planning system. METHODS AND MATERIALS This study involved 12 patients with centrally located or larger lung tumors previously treated with 7- to 9-field static beam intensity modulated radiation therapy to 50 Gy. They were rep...
متن کاملStereotactic Body Radiotherapy for Recurrent Unresectable Head and Neck Cancers.
BACKGROUND Treatment of locoregional, recurrent head and neck cancers following definitive radiotherapy has evolved during the past 30 years. Brachytherapy as well as protracted courses of systemic therapy and chemoradiotherapy result in 12-month survival rates of 40% to 50% but have high rates of severe toxicity. Given the advancements in radiotherapy targeting and delivery, stereotactic body ...
متن کاملThe importance of the optimal volume in the treatment of locally recurrent nasopharyngeal carcinoma; brachytherapy or stereotactic radiotherapy?
Introduction: Nasopharyngeal carcinoma (NPC) is commonly known as a radiosensitive tumor with the initial good response to radiation. Despite the improved outcome in loco regional control by the introduction of combining treatment, modern radiotherapy techniques and enhanced imaging studies, local recurrent after primary treatment with rate ranges from 15-58% in 5 years, stil...
متن کاملLong-term outcome and toxicity of hypofractionated stereotactic body radiotherapy as a boost treatment for head and neck cancer: the importance of boost volume assessment
BACKGROUND The aim of this study was to report the long-term clinical outcomes of patients who received stereotactic body radiotherapy (SBRT) as a boost treatment for head and neck cancer. MATERIALS AND METHODS Between March 2004 and July 2007, 26 patients with locally advanced, medically inoperable head and neck cancer or gross residual tumors in close proximity to critical structures follow...
متن کاملViability of Noncoplanar VMAT for liver SBRT compared with coplanar VMAT and beam orientation optimized 4π IMRT
PURPOSE The 4π static non-coplanar radiotherapy delivery technique has demonstrated better normal tissue sparing and dose conformity than the clinically used volumetric modulated arc therapy (VMAT). It is unclear whether this is a fundamental limitation of VMAT delivery or the coplanar nature of its typical clinical plans. The dosimetry and the limits of normal tissue toxicity constrained dose ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- International journal of radiation oncology, biology, physics
دوره 91 2 شماره
صفحات -
تاریخ انتشار 2015