Accuracy of the GlucoWatch G2 Biographer and the continuous glucose monitoring system during hypoglycemia: experience of the Diabetes Research in Children Network.

ثبت نشده
چکیده

OBJECTIVE The goal of this study was to assess the accuracy of the GlucoWatch G2 Biographer (GW2B) and the continuous glucose monitoring system (CGMS) during hypoglycemia in children and adolescents with type 1 diabetes. RESEARCH DESIGN AND METHODS During a 24-h clinical research center stay, 91 children and adolescents with type 1 diabetes (aged 3.5-17.7 years) wore one or two CGMSs, and 89 of these subjects wore one or two GW2Bs. Frequent serum glucose determinations were made during the day, overnight, and during insulin-induced hypoglycemia resulting in 192 GW2B reference pairs and 401 CGMS reference pairs during hypoglycemia (reference glucose < or =60 mg/dl). RESULTS During hypoglycemia, the median absolute difference between the 192 GW2B reference glucose pairs was 26 mg/dl and between the 401 CGMS reference glucose pairs was 19 mg/dl with 31 and 42%, respectively, of the sensor values within 15 mg/dl of the reference glucose. Sensitivity to detect hypoglycemia when the GW2B alarm level was set to 60 mg/dl was 23% with a false-alarm rate of 51%. Analyses suggested that modified CGMS sensors that became available in November 2002 might be more accurate than the original CGMS sensors (median absolute difference 15 vs. 20 mg/dl). CONCLUSIONS These data show that the GW2B and the CGMS do not reliably detect hypoglycemia. Both of these devices perform better at higher glucose levels, suggesting they may be more useful in reducing HbA1c levels than in detecting hypoglycemia.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A randomized multicenter trial comparing the GlucoWatch Biographer with standard glucose monitoring in children with type 1 diabetes.

OBJECTIVE This study assesses whether use of the GlucoWatch G2 Biographer (GW2B) in addition to standard glucose monitoring lowers HbA(1c) and reduces hypoglycemia compared with standard glucose monitoring alone. RESEARCH DESIGN AND METHODS In all, 200 subjects aged 7 to <18 years with type 1 diabetes were randomly assigned at five centers to standard glucose monitoring (usual care) or standa...

متن کامل

Detection of hypoglycemia with the GlucoWatch biographer.

OBJECTIVE Hypoglycemia is a common acute complication of diabetes therapy. The GlucoWatch biographer provides frequent and automatic glucose measurements with an adjustable low-glucose alarm. We have analyzed the performance of the biographer low-glucose alarm relative to hypoglycemia as defined by blood glucose < or = 3.9 mmol/l. RESEARCH DESIGN AND METHODS The analysis was based on 1,091 bi...

متن کامل

Rates of glucose change measured by blood glucose meter and the GlucoWatch Biographer during day, night, and around mealtimes.

OBJECTIVE The purpose of this study was to characterize the distribution of the rate of change of blood glucose for a diabetic population. RESEARCH DESIGN AND METHODS The study population consisted of 124 adults with type 1 or type 2 diabetes requiring insulin. Study participants applied a GlucoWatch Biographer during the day at home for 5 consecutive days and took finger-prick blood glucose ...

متن کامل

The need for separate performance goals for glucose sensors in the hypoglycemic, normoglycemic, and hyperglycemic ranges.

Goals for Glucose Sensors in the Hypoglycemic, Normoglycemic, and Hyperglycemic Ranges B lood glucose monitors are an important tool for people with diabetes to assess their physiological status and allow them to properly dose themselves with medication or food. The need to adjust the amount of treatment is greatest when the blood glucose level is in the hypoglycemic range because of the risk o...

متن کامل

Eight-point glucose testing versus the continuous glucose monitoring system in evaluation of glycemic control in type 1 diabetes.

CONTEXT Advantages/disadvantages of continuous vs. discrete glucose monitoring are not well documented. OBJECTIVE Compare glucose profiles from home meters vs. continuous sensors. DESIGN Randomized clinical trial conducted by the Diabetes Research in Children Network (DirecNet) to assess the utility of the GlucoWatch G2 Biographer. SETTING Home glucose measurements. PATIENTS Two hundred...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Diabetes care

دوره 27 3  شماره 

صفحات  -

تاریخ انتشار 2004