Optical coherence tomography angiography of optic disc perfusion in glaucoma.

نویسندگان

  • Yali Jia
  • Eric Wei
  • Xiaogang Wang
  • Xinbo Zhang
  • John C Morrison
  • Mansi Parikh
  • Lori H Lombardi
  • Devin M Gattey
  • Rebecca L Armour
  • Beth Edmunds
  • Martin F Kraus
  • James G Fujimoto
  • David Huang
چکیده

PURPOSE To compare optic disc perfusion between normal subjects and subjects with glaucoma using optical coherence tomography (OCT) angiography and to detect optic disc perfusion changes in glaucoma. DESIGN Observational, cross-sectional study. PARTICIPANTS Twenty-four normal subjects and 11 patients with glaucoma were included. METHODS One eye of each subject was scanned by a high-speed 1050-nm-wavelength swept-source OCT instrument. The split-spectrum amplitude-decorrelation angiography (SSADA) algorithm was used to compute 3-dimensional optic disc angiography. A disc flow index was computed from 4 registered scans. Confocal scanning laser ophthalmoscopy (cSLO) was used to measure disc rim area, and stereo photography was used to evaluate cup/disc (C/D) ratios. Wide-field OCT scans over the discs were used to measure retinal nerve fiber layer (NFL) thickness. MAIN OUTCOME MEASURES Variability was assessed by coefficient of variation (CV). Diagnostic accuracy was assessed by sensitivity and specificity. Comparisons between glaucoma and normal groups were analyzed by Wilcoxon rank-sum test. Correlations among disc flow index, structural assessments, and visual field (VF) parameters were assessed by linear regression. RESULTS In normal discs, a dense microvascular network was visible on OCT angiography. This network was visibly attenuated in subjects with glaucoma. The intra-visit repeatability, inter-visit reproducibility, and normal population variability of the optic disc flow index were 1.2%, 4.2%, and 5.0% CV, respectively. The disc flow index was reduced by 25% in the glaucoma group (P = 0.003). Sensitivity and specificity were both 100% using an optimized cutoff. The flow index was highly correlated with VF pattern standard deviation (R(2) = 0.752, P = 0.001). These correlations were significant even after accounting for age, C/D area ratio, NFL, and rim area. CONCLUSIONS Optical coherence tomography angiography, generated by the new SSADA, repeatably measures optic disc perfusion and may be useful in the evaluation of glaucoma and glaucoma progression.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Clinical Applications of Optical Coherence Tomography in Ophthalmology

Assessment of the peripapillary nerve fiber layer and macular thickness can be determined in ophthalmology using optical coherence tomography (OCT). Decreased nerve fiber layer thickness and macular ganglion cell thickness in optic nerve ischemia have been correlated with visual field loss. OCT allows deep optic nerve head evaluation which helps understand pathophysiology of diseases.  Furtherm...

متن کامل

Quantitative OCT angiography of optic nerve head blood flow

Optic nerve head (ONH) blood flow may be associated with glaucoma development. A reliable method to quantify ONH blood flow could provide insight into the vascular component of glaucoma pathophysiology. Using ultrahigh-speed optical coherence tomography (OCT), we developed a new 3D angiography algorithm called split-spectrum amplitude-decorrelation angiography (SSADA) for imaging ONH microcircu...

متن کامل

Optic Disc Perfusion in Primary Open Angle and Normal Tension Glaucoma Eyes Using Optical Coherence Tomography-Based Microangiography

PURPOSE To investigate optic disc perfusion differences in normal, primary open-angle glaucoma (POAG), and normal tension glaucoma (NTG) eyes using optical microangiography (OMAG) based optical coherence tomography (OCT) angiography technique. DESIGN Cross-sectional, observational study. SUBJECTS Twenty-eight normal, 30 POAG, and 31 NTG subjects. METHODS One eye from each subject was scan...

متن کامل

Peripapillary Intrachoroidal Cavitation and Optic Pit in a Case of High Myopia and Glaucoma

Purpose: To report a case of peripapillary intrachoroidal cavitation (choroidal schisis) and optic pit in a case of high myopia and open-angle glaucoma. Case report: A 30-year-old high myopic man was referred to our clinic for presumed peripapillary choroidal tumors. In funduscopy, there were two yellow-orange and slightly elevated peripapillary lesions in both eyes with indistinct margins. A s...

متن کامل

Optic disc perfusion in eyes with primary open angle glaucoma and normal tension glaucoma using optical coherence tomography-based microangiography

Program Number: 2957 Poster Board Number: A0306 Presentation Time: 8:30 AM–10:15 AM Optic disc perfusion in eyes with primary open angle glaucoma and normal tension glaucoma using optical coherence tomography-based microangiography Karine D. Bojikian1, Chieh-Li Chen2, Joanne C. Wen1, Qinqin Zhang2, Chen Xin2, Divakar Gupta1, Raghu C. Mudumbai1, Murray A. Johnstone1, Ruikang K. Wang2, 1, Philip ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Ophthalmology

دوره 121 7  شماره 

صفحات  -

تاریخ انتشار 2014