Photothermal coagulation of blood vessels: a comparison of high-speed optical coherence tomography and numerical modelling.

نویسندگان

  • J K Barton
  • A Rollins
  • S Yazdanfar
  • T J Pfefer
  • V Westphal
  • J A Izatt
چکیده

Optical-thermal models that can accurately predict temperature rise and damage in blood vessels and surrounding tissue may be used to improve the treatment of vascular disorders. Verification of these models has been hampered by the lack of time- and depth-resolved experimental data. In this preliminary study, an optical coherence tomography system operating at 4-30 frames per second was used to visualize laser irradiation of cutaneous (hamster dorsal skin flap) blood vessels. An argon laser was utilized with the following parameters: pulse duration 0.1-2.0 s, spot size 0.1-1.0 mm, power 100-400 mW. Video microscopy images were obtained before and after irradiations, and optical-thermal modelling was performed on two irradiation cases. Time-resolved optical coherence tomography and still images were compared with predictions of temperature rise and damage using Monte Carlo and finite difference techniques. In general, predicted damage agreed with the actual blood vessel and surrounding tissue coagulation seen in images. However, limitations of current optical-thermal models were identified, such as the inability to model the dynamic changes in blood vessel diameter that were seen in the optical coherence tomography images.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Choroidal Thickness in Psoriasis and Control Groups Using Optical Coherence Tomography

Background and Objective: One of the most common extracutaneous complications in psoriasis patients is ocular complications, which is controversial concerning its effect on choroidal thickness. This study aimed to compare the psoriasis patients with healthy individuals in terms of the thickness of the choroidal layer using the optical coherence tomography technique. Materials and Methods: In t...

متن کامل

Development of an Advanced Optical Coherence Tomography System for Radiation Dosimetry

Introduction: According to the literature, optical coherence tomography (OCT) can be used measure radiation absorbed dose. This study was carried out to design a computed tomography system for the calculation of absorbed dose and optimization of dose delivery in radiotherapy using gel dosimeters. Material and Methods: An advanced charge-coupled device based OCT system was developed in laborator...

متن کامل

Experimental Visualization of Labyrinthine Structure with Optical Coherence Tomography

Introduction:Visualization of inner ear structures is a valuable strategy for researchers and clinicians working on hearing pathologies. Optical coherence tomography (OCT) is a high-resolution imaging technology which may be used for the visualization of tissues. In this experimental study we aimed to evaluate inner ear anatomy in well-prepared human labyrinthine bones.Materials and Methods:Thr...

متن کامل

Depth-resolved blood oxygen saturation measurement by dual-wavelength photothermal (DWP) optical coherence tomography

Non-invasive depth-resolved measurement of hemoglobin oxygen saturation (SaO(2)) levels in discrete blood vessels may have implications for diagnosis and treatment of various pathologies. We introduce a novel Dual-Wavelength Photothermal (DWP) Optical Coherence Tomography (OCT) for non-invasive depth-resolved measurement of SaO(2) levels in a blood vessel phantom. DWP OCT SaO(2) is linearly cor...

متن کامل

Retinal blood flow measurement with ultrahigh-speed swept-source / Fourier domain optical coherence tomography

Doppler OCT is a functional extension of OCT that provides information on flow in biological tissues. We present a novel approach for total retinal blood flow assessment using ultrahigh speed Doppler OCT. A swept source / Fourier domain OCT system at 1050 nm was used for 3D imaging of the human retina. The high axial scan rate of 200 kHz allowed measuring the high flow velocities in the central...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Physics in medicine and biology

دوره 46 6  شماره 

صفحات  -

تاریخ انتشار 2001