Tangential intensity modulated radiation therapy (IMRT) to the intact breast

نویسندگان

  • Jenna Dean
  • Carmen J. Hansen
  • Justin Westhuyzen
  • Brett Waller
  • Kirsty Turnbull
  • Maree Wood
  • Andrew Last
چکیده

INTRODUCTION Inverse-planned intensity modulated radiation therapy (IP-IMRT) has potential benefits over other techniques for tangential intact breast radiotherapy. Possible benefits include increased homogeneity, faster planning time, less inter-planner variability and lower doses to organs at risk (OAR). We therefore conducted a pilot study of previously treated intact breast patients to compare the current forward-planned 'field-in-field' technique (FP-IMRT) with an IP-IMRT alternative. METHODS The IP-IMRT plans of 20 patients were generated from a template created for the planning system. All patients were prescribed adjuvant whole breast radiotherapy using a hypofractionated regimen of 40.05 Gy in 15 fractions over 3 weeks. Plans were assessed based on visual inspection of coverage as well as statistical analysis and compared to the clinically acceptable FP-IMRT plans. Patients were planned retrospectively in Monaco 3.2® using a laterality-specific, tangential planning template. Minor adjustments were made as necessary to meet the planning criteria in the protocol. Dose coverage, maximums, homogeneity indices and doses to OAR were recorded. RESULTS The IP-IMRT plans provided more consistent coverage (38.18 Gy vs. 36.08 Gy of D95; P = 0.005), a comparable though higher average maximum (D2 = 42.52 Gy vs. 42.08 Gy; P = 0.0001), more homogeneous plans (homogeneity index = 0.908 vs. 0.861; P = 0.01) and somewhat lower V20 heart and lung doses (0.11% vs. 0.89% for heart; 5.4% vs. 7.52% for lung) than FP-IMRT (P > 0.05). CONCLUSION Clinically acceptable plans have been generated using the IP-IMRT templates in Monaco. Improvements in consistency and quality were seen when compared to the FP-IMRT plans. The template-based process is an efficient method to inversely plan IMRT for breast patients.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of dosimetric radiotherapy of whole left- breast cancer using conventional tangential wedge-based techniques (CTT) and three intensity modulation techniques (IMRT)

Introduction: Whole breast radiotherapy after breast-conserving surgery decrease the risk of local recurrence. this study investigates the dosimetric aspects of intensity modulated radiotherapy (IMRT) compared to conventional tangential wedge-based beams techniques (CTT) of the whole breast in early stages breast cancer patients.   Materials and Methods: Co...

متن کامل

Intensity modulated radiation therapy (IMRT) technique for left breast cancer by different numbers of beam fields

Background: Intensity Modulated Radiotherapy (IMRT) can improve radiotherapy (RT) results by improving healthy tissue sparing. Additionally, IMRT provides more consistent dose deliveries and suppresses secondary tumor formation. RT is a principal treatment in breast cancer (BC). Aim: To evaluate the outcome of the Radiotherapy Plans (RTP) that use IMRT technique to left breast and other organs,...

متن کامل

Intensity modulated radiotherapy with fixed collimator jaws for locoregional left-sided breast cancer irradiation

The purpose of this study is to evaluate the intensity modulated radiotherapy (IMRT) with the fixed collimator jaws technique (FJT) for the left breast and regional lymph node. The targeted breast tissue and the lymph nodes, and the normal tissues were contoured for 16 left-sided breast cancer patients previously treated with radiotherapy after lumpectomy. For each patient, treatment plans usin...

متن کامل

Clustering of nasopharyngeal carcinoma intensity modulated radiation therapy plans based on k-means algorithm and geometrical features

Background: The design of intensity modulated radiation therapy (IMRT) plans is difficult and time-consuming. The retrieval of similar IMRT plans from the IMRT plan dataset can effectively improve the quality and efficiency of IMRT plans and automate the design of IMRT planning. However, the large IMRT plans datasets will bring inefficient retrieval result. Materials and Methods: An intensity-m...

متن کامل

3D-Conformal Radiation Therapy and Intensity-Modulated Radiation Therapy Techniques for Laryngeal Cancer Taking Parotid Glands as Organ at Risk

Background: Three-dimensional conformal radiotherapy (3D-CRT) and intensity-modulated radiotherapy (IMRT) techniques are used for the treatment of patients with laryngeal cancer. Objective: This study aimed to investigate the effects of these 2 treatment techniques on the planning target volume (PTV) (laryngeal cancer), dose homogeneity, dose of organs at...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 63  شماره 

صفحات  -

تاریخ انتشار 2016