Anterior chamber angle measurement with anterior segment optical coherence tomography: a comparison between slit lamp OCT and Visante OCT.

نویسندگان

  • Christopher Kai-shun Leung
  • Haitao Li
  • Robert Neal Weinreb
  • Jing Liu
  • Carol Yim Lui Cheung
  • Ricky Yiu Kwong Lai
  • Chi Pui Pang
  • Dennis Shun Chiu Lam
چکیده

PURPOSE To compare anterior chamber angle measurements obtained from two anterior segment optical coherence tomography (OCT) instruments and to evaluate their agreements and interobserver reproducibility. METHODS Forty-nine eyes from 49 healthy normal subjects were studied. The anterior chamber angle was imaged with the Visante anterior segment OCT (Carl Zeiss Meditec, Dublin, CA) and the slit lamp OCT (SLOCT, Heidelberg Engineering, GmbH, Dossenheim, Germany) on one randomly selected eye in each subject and measured by two independent observers. The angle-opening distance (AOD 500), the trabecular-iris angle (TIA 500), and the trabecular-iris space area (TISA 500) at the nasal and temporal angles were measured. The agreements between SLOCT and Visante OCT measurements and the interobserver reproducibility were evaluated. RESULTS The mean nasal/temporal anterior chamber angles measured by Visante OCT and SLOCT were 527 +/- 249/572 +/- 275 microm (AOD), 0.180 +/- 0.091/0.193 +/- 0.102 mm(2) (TISA), and 38.1 +/- 12.3/39.6 +/- 13.2 degrees (TIA); and 534 +/- 234/628 +/- 254 microm (AOD), 0.191 +/- 0.089/0.217 +/- 0.093 mm(2)(TISA), and 37.8 +/- 10.1/40.6 +/- 10.7 degrees (TIA), respectively. No significant difference was found between Visante OCT and SLOCT measurements except the temporal TISA (P = 0.034). The interobserver coefficient of variation ranged between 4.4% and 7.8% for Visante OCT and 4.9% and 7.0% for SLOCT. The spans of 95% limits of agreement of the nasal/temporal angle measurements between Visante OCT and SLOCT were 437/531 mm(2), 0.174/0.186 mm(2), and 25.3/28.0 degrees for AOD, TISA, and TIA, respectively. CONCLUSIONS Although Visante OCT and SLOCT demonstrate high interobserver reproducibility for anterior chamber angle measurements, their agreement was poor.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optical coherence tomography in malignant glaucoma following filtration surgery.

AIM To assess the value of slit lamp adapted optical coherence tomography (OCT) for the management of malignant glaucoma following filtration surgery. METHODS Two patients (three eyes) developed malignant glaucoma following filtration surgery for primary open angle glaucoma (POAG). With slit lamp adapted OCT it was possible to image non-invasively the anterior chamber angle structures during ...

متن کامل

Reference values for anterior chamber morphometrics with swept-source optical coherence tomography in a Caucasian population

Purpose The aim of this study is to generate reference values for anterior chamber morphometrics to facilitate the interpretation of anterior chamber images acquired with swept-source optical coherence tomography (SS-OCT) in a Caucasian population. Materials and methods Non-glaucomatous Caucasian subjects, who were newly referred to the outpatient department of the University Eye Clinic Maast...

متن کامل

High-speed optical coherence tomography as a reliable adjuvant tool to grade ocular anterior chamber inflammation.

PURPOSE To evaluate the high-speed anterior segment optical coherence tomography (AS-OCT) grading of the AS inflammation in patients with ocular inflammation. METHODS A retrospective consecutive case series study. Patients with clinically visible AS inflammation in at least one eye underwent AS-OCT (Visante; Zeiss Meditec) with three to eight line scans per eye, performed by a trained masked ...

متن کامل

The complementary benefit of anterior segment optical coherence tomography in penetrating keratoplasty

PURPOSE To evaluate the utility of anterior segment optical coherence tomography (AS-OCT) assessment in the pre- and postsurgical management of full-thickness corneal grafts. METHODS Seventy eyes of 58 patients who had penetrating keratoplasty were included in the study. High resolution AS-OCT scans of the cornea and the anterior segment were performed before and after transplantation in 17 e...

متن کامل

Spectral domain optical coherence tomography study of pearl-like lesions in the anterior chamber

AIM To study the morphological pattern of pearl-like lesions in the anterior chambers of children before and after management using anterior segment spectral domain optical coherence tomography (SD-OCT). PATIENTS AND METHODS This was a prospective, observational cross-sectional study of patients presenting with peculiar pearl-like lesions in the anterior chamber of their eyes. 1 mL of betamet...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Investigative ophthalmology & visual science

دوره 49 8  شماره 

صفحات  -

تاریخ انتشار 2008