TightRope fixation of complex acromioclavicular separation: A high-wire act

نویسندگان

  • Diana L. Lam
  • Felix S. Chew
چکیده

Numerous techniques have evolved for acromioclavicular joint fixation over the past decade to help decrease the risk of hardware complications and improve patient satisfaction. One of these techniques involves the TightRope system, which employs two titanium endobuttons to help reduce and secure the coracoclavicular joint. Clinical outcomes have been favorable, as orthopedic surgeons have gained more experience using this nonrigid system. It is important for radiologists to be aware of the radiographic appearance of this device and its associated complications.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A New Technique for Solving Tightrope Cutout during Acromioclavicular Joint Fixation: A Case Report

Acromioclavicular joint (ACJ) dissociation is one of the common injuries affecting adults. The stability of ACJ largely depends on the integrity of acromioclavicular ligament, coracoclavicular ligament, capsule, trapezius muscle and deltoid muscle. The injury has been classified by Rockwood into six types and treatment options can be guided by the classification. TightRope fixation is one of th...

متن کامل

Arthroscopic fixation for acute acromioclavicular joint disruption using the TightRope device.

PURPOSE To review outcome after arthroscopic fixation for acute acromioclavicular (AC) joint dislocation using the TightRope device. METHODS Records of 15 men and 2 women aged 19 to 52 (mean, 35) years who underwent arthroscopic fixation using the TightRope device for acute (<3 weeks) AC joint dislocation of Rockwood type III (n=6), type IV (n=1), and type V (n=10) were reviewed. Outcome was ...

متن کامل

A technique of distal clavicle fracture fixation using the tightrope procedure.

ABSTRACT We present here a technique of fracture stabilization using the Tightrope procedure in a patient with a widely displaced Neer type IIB distal clavicle fracture. The Tightrope system, typically used for stabilization of acromioclavicular joint dislocation, has not been widely described for distal clavicle fractures. The patient achieved satisfactory results after surgery; we feel that t...

متن کامل

Evaluation of arthroscopic stabilization of acute acromioclavicular joint dislocation using the TightRope system.

The purpose of this study was to evaluate the results of the arthroscopic treatment of acute acromioclavicular dislocation using the TightRope system (Arthrex, Naples, Florida). Between January 2006 and May 2007, ten shoulders in 10 patients with acute acromioclavicular joint dislocation (Rockwood types IV and V) underwent arthroscopic acromioclavicular joint stabilization using the TightRope. ...

متن کامل

Coracoid fracture with recurrent AC joint separation after Tightrope repair of AC joint dislocation

We present a case of failure of acromioclavicular joint (ACJ) reduction that was performed with low-profile, double-metallic button technique (Tightrope; Arthrex Inc). The patient presented with coracoid fracture and loss of reduction within eight weeks of surgery.

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 6  شماره 

صفحات  -

تاریخ انتشار 2011