Determination of the dead-time losses in NaI(Tl) gamma-ray spectrometer

نویسندگان

  • D. Grozdanov
  • I. Ruskov
  • N. Janeva
چکیده

The 12 NaI(Tl)-detector gamma-ray spectrometry system (GSS) “Romashka”[1,2] has recently been equipped with a new computer controlled HVSys 16 channel high-voltage power supply with preselected single channel polarity [3] (Fig.1). In order to do some preliminary checks of the GSS chains’ characteristics, a single channel gamma-spectrometry tract was commissioned. It was consist of a single Romashka’s section NaI(Tl) crystal, optically coupled with a photo-multiplier tube FEU-110, a POLON TM Active Filter Amplifier and an EG&G ORTEC TRUMP TM -2k Multichannel Buffer (MCB) PCcompatible plug-in card, run by Maestro TM MCA Emulation and Analysis Software for Windows®, having real-time and life-time acquisition presets [4]. Two calibration sources method was applied for obtaining the effective dead-time (and dead-time losses) of a single spectrometry chain. It was used, also, to determine the dead-time of the chain when a Parsek LLC desktop 8k multichannel analyzer (MCA) with no live-time measured/indication possibility [5]. The testing of the whole gamma-ray spectrometry system with the new HV power supply has been recently accomplished. It is planned to use the modernized “Romashka” GSS at the JINR FLNP resonance neutron time-of-flight (TOF) spectrometer IREN, for investigation of the gamma-rays emission from neutron inelastic scattering, capture and fission reactions, using the multiplicity method [2].

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Comparative Study of Field Gamma-ray Spectrometry by NaI(Tl) and HPGe Detectors in the South Caspian Region

Natural radionuclides present in soil as well as certain anthropogenic radionuclides released to the environment are the major contributors to terrestrial outdoor exposures. In the assessment of human exposures from environmental radioactivity, besides the conventional method of soil and vegetation sampling combined with laboratory based analyses of environmental media, the other choice would b...

متن کامل

Determination of the flux of a neutron radioisotope source through gold activation method

Introduction: In recent years, the use of neutrons has increased in various fields such as medicine and industry. One of the important applications of neutrons is in medical research. Neutrons have greater linear energy transfer than gamma rays and are considered more dangerous radiation. Hence, the detection and determination of neutron dose is a very important and vital issu...

متن کامل

Replacement of a Photomultiplier Tube in a 2-inch Thallium-doped Sodium Iodide Gamma Spectrometer with Silicon Photomultipliers and a Light Guide

The thallium-doped sodium iodide [NaI(Tl)] scintillation detector is preferred as a gamma spectrometer in many fields because of its general advantages. A silicon photomultiplier (SiPM) has recently been developed and its application area has been expanded as an alternative to photomultiplier tubes (PMTs). It has merits such as a low operating voltage, compact size, cheap production cost, and m...

متن کامل

Radiation attenuation of boron doped clay for 662, 1173 and 1332 keV gamma rays

Background: Radiation shielding properties is an important for a material wish can be used the photon attenuation coefficients of clay produced using different rate of boron have been measured for the purpose of radioactive waste disposal. Materials and Methods: The measurement has been performed using gamma spectrometer contains NaI (Tl) detector at the photon energies of 662, 1173 an...

متن کامل

Sequential monitoring of cosmic-ray neutrons and ionizing components in Japan

A fixed-point measurement of cosmic-ray intensity has being continued at Chiba, near Tokyo in Japan to obtain the time-sequential data. High efficiency neutron rem counter and Multi-sphere neutron Spectrometer (Bonner Sphere: BS) were used for the measurement of cosmic-ray neutron components and for the evaluation of the cosmic-ray ionizing components, NaI(Tl) scintillation spectrometer was emp...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014