Conversion of external fixation to internal fixation in a non-acute, reconstructive setting: a case series

نویسندگان

  • T. Monni
  • F. F. Birkholtz
  • P. de Lange
  • C. H. Snyckers
چکیده

The aim of the study is to determine the outcomes in patients who underwent conversion from an external fixator to an internal fixation device. This is a retrospective review of 18 patients (24 limbs) who underwent conversion from external to internal fixation. The patients had external fixators applied for traumatic bone defects or congenital deformities. Conversion to internal fixation was performed for reasons of patient dissatisfaction with external fixation, pin track sepsis, persistent non-union or refracture. The complexity of cases was graded using Paley's level of difficulty score. Patients were either converted acutely or delayed. Internal fixation devices were either intramedullary nails or plate and screws. Outcome was regarded as excellent if the patients were fully weight-bearing and pain-free on a mechanically well-aligned limb and without need for further surgery: good if the patient required subsequent surgery to achieve union and poor if irreversible complications occurred. Acute conversions (fixator removal and introduction of internal fixation device at same surgery) were done in 19 limbs and delayed conversion (interval between fixator removal and internal fixation) in 5. In the acute group, 17 limbs (89.4 %) had at least a good outcome, 16 of these limbs had an excellent result. Two limbs (10.6 %) had a poor result and required amputation. Both cases were after acute conversion to intramedullary nails; the original presenting diagnosis was of an infected non-union of the tibia and both had Paley scores above 7. In the delayed conversion group, all limbs (100 %) had at least a good outcome, with 4 limbs (80 %) having an excellent result. The mean external fixator time was 185 days (61-370). Both the cases with poor outcomes had longer external fixation times. This series supports the practice of conversion of external fixation to internal fixation with the majority of patients attaining good results. It identifies that plate devices appear to produce fewer deep sepsis complications, as compared to intramedullary nails, particularly when the original presenting diagnosis is a septic non-union.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Treatment of Open Tibial Fractures: Convert-ing or Continuing External Fixation?

Background: The treatment of open tibial fractures is still an orthopaedic challenge and full of complications. In many cases the use of external fixator that has been known as a non-union machine is obligatory with a high incidence of pin track infection and other complications. The aim of this study was to compare the use of external fixation as a definite method for treatment of open tibial ...

متن کامل

Damage control orthopaedics in the context of battlefield injuries: the use of temporary external fixation on combat trauma soldiers.

INTRODUCTION The purpose of this study was to analyze the use of temporary external fixation within the perspective of a damage control orthopedics attitude in the management of battlefield extremity injuries. HYPOTHESIS Damage control orthopaedics (DCO) is a valuable treatment option for easy and rapid limb fracture stabilization in an unfavorable surgical environment. METHODS Sixteen Fren...

متن کامل

The Outcomes of Pilon Fracture Treatment: Primary Open Reduction and Internal Fixation Versus Twostage Approach

Background: Pilon fracture is one of the challenging injuries in orthopedic surgery. Associated soft tissue injury is animportant factor in choosing treatment options. Two major methods of treatment are considered as one-stage openreduction internal fixation (ORIF) and two-stage treatment (primary external fixation and secondary ORIF). The latter ismost accepted in literature. In the current st...

متن کامل

درمان شکستگی‌های پیچیده پلاتوی تیبیا به‌روش جراحی هیبرید اکسترنال فیکساتور: گزارش 15 مورد

Background: Proper knee function is essential for daily activity. Since almost all complex tibial plateau fractures involve soft tissue compromise, there is some controversy as to the best treatment method. Currently, progress toward indirect reduction and external fixation, such as the hybrid external fixator, with minimal complications is underway. Herein we evaluate the outcomes of complex t...

متن کامل

DISPLACED- COMMINUTED INTRAARTICULAR FRACTURES OF THE ADULT DISTAL HUMERUS: FUNCTIONAL RESULTS AFTER INTERNAL FIXATION

Background: Intra-articular T- type or Y- type fractures of the distal end of the humerus are relatively rare, and consequently few surgeons will be able to attain extensive experience with the surgical treatment of these injuries. The current emphasis is on operative intervention with rigid internal fixation and early mobilization. Methods: In this prospective and retrospective study, we r...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 8  شماره 

صفحات  -

تاریخ انتشار 2013