Potential for preventing spread of fungi in air-conditioning systems constructed using copper instead of aluminium.

نویسندگان

  • L Weaver
  • H T Michels
  • C W Keevil
چکیده

AIMS As copper has been previously suggested as an antimicrobial surface, we tested the effectiveness of copper as an antifungal surface which could be used in air-conditioning systems as an alternative to aluminium. METHODS AND RESULTS Coupons of copper (C11000) and aluminium were inoculated with fungal isolates (Aspergillus spp., Fusarium spp., Penicillium chrysogenum and Candida albicans) for various time periods. Culture on potato dextrose agar and an in situ viability assay using the fluorochrome FUN-1 were used to determine whether spores had survived. The results showed increased die off of fungal isolates tested compared to aluminium. In addition, copper also prevented the germination of spores present, thereby reducing the risk of the release of spores. CONCLUSIONS Copper offered an antifungal surface and prevented subsequent germination of spores present. FUN-1 demonstrated that fungal spores entered into a viable but not culturable (VBNC) state on copper indicating the importance of using such methods when assessing the effect of an antifungal as culture alone may give false results. SIGNIFICANCE AND IMPACT OF STUDY Copper offers a valuable alternative to aluminium which could be used in air-conditioning systems in buildings, particularly in hospital environments where patients are more susceptible to fungal infections.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Sustainability of Automobile Air- Conditioning System Using Refrigerant R1234yf Instead of R134a

Air conditioning refrigerant R134a has value of global warming potential (GWP) 1300, which is much higher than MAC Directive (GWP below 150) passed in July 2006. This prompted a search for alternative refrigerant with GWP value less than 150. R1234yf is a new refrigerant which has lower GWP value of 4. Effect of blower speed has been compared and flammability issue of R1234yf has been addre...

متن کامل

Passive Energy Air-to-Water Heat Pipe Based Heat Exchanger and its Potential of Air Pre-cooling in Air Conditioning Systems for Iran Climate

Air pre-cooling equipment is normally being employed in air-conditioning systems for pre-cooling the ambient outdoor air to enhance the air-conditioning systems performance. In this study, the potential of a passive water-to-air heat pipe based heat exchanger (HPHEX) for air pre-cooling purpose in air-conditioning systems for the high cooling load demanding regions of Iran was investigated. To ...

متن کامل

Designing Fuzzy Controller for Air Conditioning Systems in order to Save Energy Consumption and Provide Optimal Conditions in Closed Environments (Indoors)

Today air conditioning systems have been considered by all people as one of welfarerequirements in buildings and closed environments. Since a considerable part of energy lossoccurs in ordinary modern systems, new strategies and solutions are developed in the field inorder to save amount of energy consumption and observe environmental considerations. Fuzzycontrol is one of these methods which pr...

متن کامل

Thermal modeling of mini-channel and laminated Types evaporator in mobile air conditioning system

In this paper, mini-channel type evaporator which is new in mobile air conditioning (MAC) or automotive air conditioning (AAC) systems is thermally modeled. The performance of mini-channel evaporator is also compared with the laminated evaporator which is being currently used in automotive industries. The mini-channel evaporator was constructed of two rows of parallel flow mini-channel tubes...

متن کامل

Effect of Using Evaporative Condenser Instead of Air Condenser in Window-air Conditioners

In this paper, the application of evaporative cooling for refrigeration cycle to reduce power consumption in hot climates is emphasized. Experimental and analytical investigations were performed in order to specify the effect of evaporative cooling condenser instead of the commonly used air cooling condenser in window-air-conditioners. Evaporative condenser can reject more heat, thereby preve...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Letters in applied microbiology

دوره 50 1  شماره 

صفحات  -

تاریخ انتشار 2010