Bare Metal Stent Infection: Case Report and Literature Review

نویسندگان

  • Merrill A Krolick
  • James L. Dowling
  • Christopher Edwards
  • James Lauren Dowling
چکیده

A 75 year old female who previously underwent subclavian artery bare metal stenting presented with hemoptysis, left chest, neck and back pain. A computed tomography angiogram revealed a dissected left subclavian artery with migration and perforation of previously placed bare metal stents and hemopneumothorax, which suggested a large abscess formation. Stabilization of the dissected subclavian artery was done with placement of an 8×38 mm covered endovascular stent. Ultimately, a thoracotomy was done for investigation of a suspected abscess and infected stents. Cultures taken from both free fluid and center of abscess cultivated Staphylococus aureus and Peptostreotpcoccus prevotii. Perioperative bronchoscopy and esophagogastroduodenoscopy ruled out a Broncial fistula formation. The patient was ultimately transferred to a tertiary care facility for evaluation of subclavian bypass and removal of the infected devices. Given the large increase in percutaneous procedures, it would be expected that endovascular device infection would also rise; however, few cases have been reported as research on this topic is difficult to undertake. High clinical suspicion is usually needed to make the diagnosis of infected endovascular devices. The detection of infected endovascular devices is often found with incidental imaging procedures. The most commonly cultivated bacterium in infected stents has been Staphylococcus species. Treatment of endovascular device infections mirrors that of traditional surgical graft infections with removal of infected hardware. This case report adds to the body of evidence in regards to infected endovascular devices, which are relatively uncommon, seldom researched, and hard to diagnose without significant suspicion or incidental findings on imaging.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Iliac Artery Reconstruction with Femoral Vein After Bare Metal Stent Infection

INTRODUCTION Primary infection of a bare metal stent is a rare condition, associated with significant morbidity and mortality. Definitive treatment includes stent removal and arterial reconstruction. REPORT This study details a common iliac stent infection after re-intervention for iliac stent occlusion, complicated by pseudoaneurysm formation and septic embolisation. Potential risk factors f...

متن کامل

Stent thrombosis caused by metal allergy complicated by protein S deficiency and heparin-induced thrombocytopenia: a case report and review of the literature

A 43-year-old woman recipient of a bare metal coronary stent during an acute anterior myocardial infarction was repeatedly hospitalized with recurrent stent thrombosis (ST) over the following 3 years. Emergent coronary angiography showed a thrombus in the in-stent segment of the proximal left anterior descending artery. We repeatedly aspirated the thrombus, which immediately reformed multiple t...

متن کامل

An unusual case of ST-segment elevation myocardial infarction following a late bare-metal stent fracture in a native coronary artery: a case report

INTRODUCTION A bare-metal stent fracture as a cause of acute coronary thrombosis and consequently of acute coronary syndrome is a rare clinical event that, to the best of our knowledge, has previously not been reported. A stent fracture is a rare complication arising from percutaneous coronary intervention. CASE PRESENTATION We present, to the best of our knowledge, the first documented case ...

متن کامل

بررسی نتیجه کلینیکی بلند مدت آنژیوپلاستی با استنت فلزی در بیماران مبتلا به بیماری عروق کرونر در بیمارستان فاطمه زهرا (س) ساری از سال 1383 تا سال 1385

Background and Purpose:Coronary artery Stenting is known to improve the outcome for ischemic heart disease. Many clinical studies have been performed to determine the long-term outcome of coronary Stenting and most of them were based on first-generation bare-metal Stents. The aim of this study is to evaluate long-term (24 6.4 month) results of second-generation bare metal stent. Materials an...

متن کامل

Brief review: coronary drug-eluting stents and anesthesia.

PURPOSE Anesthesiologists managing patients with drug-eluting stents (DES) face the challenge of balancing the risks of bleeding vs perioperative stent thrombosis (ST). This article reviews DES and the influence of antiplatelet medications related to their use. A perioperative management algorithm is suggested. Novel P2Y12 antagonists currently under investigation, including cangrelor and prasu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014