Endoscopic optical coherence tomography with a modified microelectromechanical systems mirror for detection of bladder cancers.

نویسندگان

  • Tuqiang Xie
  • Huikai Xie
  • Gary K Fedder
  • Yingtian Pan
چکیده

Experimental results of a modified micromachined microelectromechanical systems (MEMS) mirror for substantial enhancement of the transverse laser scanning performance of endoscopic optical coherence tomography (EOCT) are presented. Image distortion due to buckling of MEMS mirror in our previous designs was analyzed and found to be attributed to excessive internal stress of the transverse bimorph meshes. The modified MEMS mirror completely eliminates bimorph stress and the resultant buckling effect, which increases the wobbling-free angular optical actuation to greater than 37 degrees, exceeding the transverse laser scanning requirements for EOCT and confocal endoscopy. The new optical coherence tomography (OCT) endoscope allows for two-dimensional cross-sectional imaging that covers an area of 4.2 mm x 2.8 mm (limited by scope size) and at roughly 5 frames/s instead of the previous area size of 2.9 mm x 2.8 mm and is highly suitable for noninvasive and high-resolution imaging diagnosis of epithelial lesions in vivo. EOCT images of normal rat bladders and rat bladder cancers are compared with the same cross sections acquired with conventional bench-top OCT. The results clearly demonstrate the potential of EOCT for in vivo imaging diagnosis and precise guidance for excisional biopsy of early bladder cancers.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Endoscopic optical coherence tomography based on a microelectromechanical mirror.

An endoscopic optical coherence tomography (OCT) system based on a microelectromechanical mirror to facilitate lateral light scanning is described. The front-view OCT scope, adapted to the instrument channel of a commercial endoscopic sheath, allows real-time cross-sectional imaging of living biological tissue via direct endoscopic visual guidance. The transverse and axial resolutions of the OC...

متن کامل

Endoscopic optical coherence tomography with new MEMS mirror - Electronics Letters

Introduction: Optical coherence tomography (OCT) is a new optical imaging technique that can provide cross-sectional images of biological tissue, highly desirable for imaging diagnosis of superficial lesions [1]. OCT can delineate tissue micro morphology, holding the potential for non-invasive optical biopsy [1, 2]. In recent years, the development of real-time, high-performance, reliable and l...

متن کامل

Optically-modulated MEMS Scanning Endoscope for Optical Coherence Tomography

This paper presents a novel configuration of a MEMS scanning endoscope that is actuated by external optical modulation. Light at a wavelength in the 1550nm range is used to modulate a scanning MEMS mirror, and wavelength of 1310nm, commonly used for optical coherence tomography (OCT), is used for the probe beam. This novel approach provides for the operation of a scanning endoscope without the ...

متن کامل

In vivo three-dimensional spectral domain endoscopic optical coherence tomography using a microelectromechanical system mirror.

A biopsy is a well-known medical test used to evaluate tissue abnormality. Biopsy specimens are invasively taken from part of a lesion and visualized by microscope after chemical treatment. However, diagnosis by means of biopsy is not only variable due to depth and location of specimen but may also damage the specimen. In addition, only a limited number of specimens can be obtained, thus, the e...

متن کامل

Two-axis magnetically-driven MEMS scanning catheter for endoscopic high-speed optical coherence tomography.

A two-axis scanning catheter was developed for 3D endoscopic imaging with spectral domain optical coherence tomography (SD-OCT). The catheter incorporates a micro-mirror scanner implemented with microelectromechanical systems (MEMS) technology: the micro-mirror is mounted on a two-axis gimbal comprised of folded flexure hinges and is actuated by magnetic field. The scanner can run either static...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Applied optics

دوره 42 31  شماره 

صفحات  -

تاریخ انتشار 2003