A significantly improved apparatus for the isopiestic measurement of thermodynamic activities at elevated temperatures is described. Details of the new design and of an analysis of the propagation of the experimental errors are presented. The apparatus was tested by measurements of calcium chloride against sodium chloride at 353.15 K. Accuracies of better than 0.1% in the osmotic coefficient are routinely achieved. Data are also given for the osmotic coefficient of aqueous sodium hydroxide solutions at 353.15 K as a function of molality ~up to 13 mol/kg!, measured with respect to both sodium chloride and calcium chloride solutions as reference electrolytes. © 1997 American Institute of Physics. @S0034-6748~97!03106-7#

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Application of T-shape Friction T test for Ti-6Al-4V Alloy at Elevated Temperatures

There are several parameters that have significant influence in metal forming process. One of the most important of them is friction coefficient. Friction can change the pattern of metal flow and the force needed for deformation. It is necessary to determine the friction coefficient to study the effect of friction on metal forming process. This study is concerned with numerical and experimental...

متن کامل

Improved apparatus and procedures for the measurement of solubility of rapidly equilibrating solid–liquid systems to 90°C

An improved apparatus for measuring solubilities of solid–liquid systems at temperatures to 90 °C is described. The apparatus has a high capacity ~up to 56 samples! and a long term temperature stability of 63 mK. The design allows the saturated solution to be multiply sampled and microfiltered at the equilibration temperature, making it particularly suited to rapidly equilibrating systems. The ...

متن کامل

An apparatus for performing microtensile tests at elevated temperatures inside a scanning electron microscope

In this paper, we introduce an apparatus to perform microtensile tests at elevated temperatures inside a scanning electron microscope. The apparatus has a stroke of 250 lm with a displacement resolution of 10 nm and a load resolution of 9.7 lN. Measurements at elevated temperatures are performed through use of two silicon-based micromachined heaters that support the sample. Each heater consists...

متن کامل

Accelerated Heat Aging Study of Phenolic/Basalt Fiber Reinforced Composites

One of the greatest impediments to use polymer-matrix composites is their susceptibility to degradation when exposed to the elevated temperatures and the limited knowledge on the thermal and mechanical properties of these composites at such temperatures. The objective of this study is to evaluate the effects of accelerated heat aging on the tensile properties of the Woven Basalt/Phenolic (WBP) ...

متن کامل

Influence of High Temperatures on Flexural Strength of Foamed Concrete Containing Fly Ash and Polypropylene Fiber

In this study, the elevated temperature flexural strengths of lightweight foamed concrete (LFC) containing fly ash (FA) and polypropylene fiber (PF) was investigated experimentally and statistically. The variables included were the temperature degrees (in a range of 20 to 600°C), LFC densities of 600, 800, 1000, 1200 and 1400 kg/m3 and additive content. Two mixes were made by replacing 15% and ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 1997