Potential for dose escalation in the postprostatectomy setting with intensity-modulated radiation therapy: a dosimetric study using EORTC consensus guidelines for target volume contours.

نویسندگان

  • Amy Harrison
  • Matthew Studenski
  • Arthur Harvey
  • Edouard J Trabulsi
  • Ying Xiao
  • Yan Yu
  • Adam P Dicker
  • Timothy N Showalter
چکیده

PURPOSE Radiation therapy (RT) is delivered as adjuvant and salvage therapy after radical prostatectomy for prostate cancer. Interest in dose escalation in this setting may necessitate more advanced RT techniques, such as intensity modulation. This study was designed to compare intensity-modulated radiation therapy (IMRT) versus 3-dimensional conformal radiation therapy (3DCRT) planning. METHODS Twenty patients were identified who received post--radical prostatectomy RT with 4-field, 3DCRT plans to 68.4 Gy. Contours were revised to comply with the European Organization for Research and Treatment of Cancer consensus guidelines. The IMRT plans with 5 versus 9 coplanar fields were compared for 10 patients. Then the 9-field IMRT plans were compared to 3DCRT in all 20 patients. Differences in dose-volume histogram values were evaluated using 2-tailed paired t tests. Cone beam computed tomographic images were analyzed to evaluate rectum doses in the treatment position during the RT course. The IMRT plans to 72.0 Gy were compared to 3DCRT to 68.4 Gy to be able to consider potential use in dose escalation. RESULTS The 9-field IMRT plans (vs 3DCRT) improved bladder mean dose and volume receiving 65 Gy or more (V65), as well as rectum mean dose (31.6 Gy vs 36.1 Gy; P < .001), volume receiving 75% or more of the prescription dose (24.4% vs 31.0%; P < .001), and V65 (10.5% vs 20.0%; P < .001). Advantages of IMRT were at the cost of small increases in maximum point doses delivered to the bladder and rectum. Cone beam computed tomographic images (n = 132) were analyzed for 8 patients; rectum mean dose and V65 were also improved by IMRT on these scans. IMRT allowed increasing dose to 72.0 Gy with similar bladder and rectum mean doses, V65, and V40 compared to 3DCRT to a total dose of 68.4 Gy. CONCLUSIONS The IMRT improves dosimetric parameters for the rectum and bladder, which may allow dose escalation after radical prostatectomy. Future studies should determine whether these advantages translate into improved clinical outcomes for prostate cancer patients.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Dosimetric Effects of Different Multileaf Collimator Widths on Physical Dose Distributions

Introduction: Geometric changes in the multileaf collimator (MLC) led to dosimetric considerations in intensity-modulated radiation therapy (IMRT) due to the number and size of the pixels in the intensity map, which are determined by the MLC leaf width. In this study, we evaluated the dosimetric effects of different MLC widths on physical dose distributions for IMRT plans. Materials and Method...

متن کامل

3D-Conformal Radiation Therapy and Intensity-Modulated Radiation Therapy Techniques for Laryngeal Cancer Taking Parotid Glands as Organ at Risk

Background: Three-dimensional conformal radiotherapy (3D-CRT) and intensity-modulated radiotherapy (IMRT) techniques are used for the treatment of patients with laryngeal cancer. Objective: This study aimed to investigate the effects of these 2 treatment techniques on the planning target volume (PTV) (laryngeal cancer), dose homogeneity, dose of organs at...

متن کامل

Dosimetric Evaluation of Volumetric Modulated Arc Therapy (VMAT) and Intensity Modulated Radiotherapy (IMRT) Using AAPM TG 119 Protocol

Background: The commissioning accuracy of Volumetric Modulated Arc Therapy (VMAT) need to be evaluated.Objective: To test and evaluate commissioning accuracy of VMAT based on the TG 119 protocols at local institution. Material and Methods: The phantom, structure sets, VMAT and IMRT beam parameter setup, dose prescriptions and planning objectives were following TG 119 guidelines to c...

متن کامل

Dosimetric verification of pre-treatment intensity modulated radiation therapy in the commissioning process

Background: Commissioning tests are recommended before implementing Intensity Modulated Radiation Therapy. This study evaluated five different plans of IMRT mocks for different modulation indices. Materials and Methods: IMRT tests were done in slab phantom for both 6MV and 15 MV photon energies using a 2D array ion chamber dosimeter. Results: The acceptance criteria were based on 3% /3mm. All t...

متن کامل

The evaluation of lung doses for radiation pneumonia risk in stereotactic body radiotherapy: A comparison of intensity modulated radiotherapy, intensity modulated arc therapy, cyberknife and helical tomotherapy

Background: Radiation Pneumonia (RP) is one of the most extensive side effects in Stereotactic Body Radiotherapy (SBRT) of lung cancer. SBRT are performed by means of Intensity Modulated Radiotherapy (IMRT), Intensity Modulated Arc Therapy (IMAT), CyberKnife (CK) or Helical Tomotherapy (HT) treatment methods. In this study, we performed a plan study to determine the plan parameter such as the M...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Practical radiation oncology

دوره 1 2  شماره 

صفحات  -

تاریخ انتشار 2011