Circuit Models for Conducted Susceptibility Analyses of Multiconductor Shielded Cables

نویسندگان

  • Saih Mohamed
  • Rouijaa Hicham
  • Ghammaz Abdelilah
چکیده

This paper presents circuit models to analyze the conducted susceptibility of multiconductor shielded cables in frequency domains using Branin’s method, which is referred to as the method of characteristics. These models, which can be used directly in the time and frequency domains, take into account the presence of both the transfer impedance and admittance. The conducted susceptibility is studied by using an injection current on the cable shield as the source. Two examples are studied; a coaxial shielded cable and shielded cables with two parallel wires (i.e., twinax cables). This shield has an asymmetry (one slot on the side). Results obtained by these models are in good agreement with those obtained by other methods. Keywords—Circuit models, multiconductor shielded cables, Branin’s method, coaxial shielded cable, twinax cables.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Electromagnetic Waves Propagation and Detection in Shielded Dielectric Power Cables

Partial discharge occurs a lot in shielded dielectric power cables. Partial discharge pulses are high-frequency electromagnetic waves that propagate in the shielded dielectric power cables. This chapter will study partial discharge propagation and detection in shielded dielectric power cables.

متن کامل

Ground Return Current Behaviour in High Voltage Alternating Current Insulated Cables

The knowledge of ground return current in fault occurrence plays a key role in the dimensioning of the earthing grid of substations and of cable sealing end compounds, in the computation of rise of earth potential at substation sites and in electromagnetic interference (EMI) on neighbouring parallel metallic conductors (pipes, handrails, etc.). Moreover, the ground return current evaluation is ...

متن کامل

DC Field Test for Medium-Voltage Cables: Why Can No One Agree?

Industry standards for shielded medium-voltage cables (5–46 kV) have recently been revised, changing the dc test voltages for field tests and test durations and limiting tests to newly installed cables. The following industry groups’ specifications and standards provide different guidelines for dc field tests for cross-linked polyethylene and ethylene propylene rubber insulated cables: IEEE, In...

متن کامل

Finite Element Analysis of Five-Transmission Lines Embedded in Four-Layered Dielectric Media

Development of very high speed integrated circuits is currently of great interests for today’s technologies. This paper presents the quasi-TEM approach for the accurate parameters extraction of multiconductor transmission lines interconnect in four-layered dielectric region using the finite element method (FEM). We illustrate that FEM is accurate and effective for modeling multilayered multicon...

متن کامل

Modeling of Multiconductor Microstrip Systems on Microwave Integrated Circuits

The microstrip line is widely used as the planar transmission line in microwave integrated circuits and high speed interconnecting buses. In this paper, we use COMSOL multiphysics to study multiconductor microstrip systems on microwave integrated circuits. We specifically illustrate the modeling of open four and five conductors systems. We successfully demonstrated the calculation of the capaci...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2015