Economically affordable anatomical kidney phantom with calyxes for puncture and drainage training in interventional urology and radiology
نویسندگان
چکیده
BACKGROUND Trends in interventional radiology and urology training are orientated towards reducing costs and increasing efficiency. In order to comply with the trends, we propose training on inexpensive patient-specific kidney phantoms. PURPOSE To develop a new kidney phantom for puncture and drainage training in interventional urology and radiology, and to evaluate their anatomical correctness and suitability for training compared to the traditional way of training on home-made phantoms. MATERIAL AND METHODS A CASE STUDY FOR VALIDATION OF KIDNEY PHANTOMS WAS CONDUCTED WITH NINE RADIOLOGY STUDENTS DIVIDED INTO TWO GROUPS: one trained on standard home-made training phantom (n = 4) and the other on our kidney phantoms (n = 5). Another test phantom was used to evaluate the effectiveness of the training of the two groups. The tests were video recorded and analyzed. Duration of the procedure was used as the primary indicator of procedure's quality. Comparison tests were also conducted with professional radiologists. Anatomical correctness of the kidney phantom was evaluated by comparing the post mortem kidney scans with reconstructed models from CT scans. Subjective feedback was also collected from the participants. Wider use of kidney phantoms was analyzed. RESULTS The average volumetric difference between post mortem kidney scans and reconstructed CT kidney models was 4.70 ± 3.25%. All five students practicing on the kidney phantom improved their performance and the results were almost equal to the results of the professional radiologist while in the other group two students out of four trained on standard home-made training phantoms failed to improve their performance. However, the small number of test subjects prevents us from drawing general conclusions about the efficiency of the new practice. The kidney phantoms were found usable also for nephrostomy catheter placement training under fluoroscopy. CONCLUSION The feedback from radiologists showed that the anatomically correct features of the phantom is an added value for the training and has a potential to increase the quality of minimally invasive procedures in general.
منابع مشابه
Percutaneous puncture of renal calyxes guided by a novel device coupled with ultrasound.
PURPOSE To evaluate the efficiency of a novel device coupled with ultrassound for renal percutaneous puncture. MATERIALS AND METHODS After establishing hydronephrosis, ten pigs had three calyxes of each kidney punctured by the same urology resident, with and without the new device ("Punctiometer"). Time for procedure completion, number of attempts to reach the calyx, puncture precision and pu...
متن کاملCase Report: Circumaortic Left Renal Vein
Awareness of the variation and renal vascular abnormality at retroperitoneal space surgeries such as kidney surgery and transplantation is very important and necessary. Complexity in the veins development of the kidney area of fetus leads to a series of changes in the production of these veins, including the extra kidney vein, and the posterior aorta vein. In this case report, we present a case...
متن کاملAssessment of patients’ entrance skin and effective dose in a mathematical human phantom for the most common interventional radiological examinations
Introduction: Nowadays, we are witnessing an exponential use of interventional radiology techniques in different communities. After CT, interventional techniques are the second factor of increasing patients’ doses in different societies. Measuring patient doses from aforementioned methods has been recommended by many radiation protection professional organizations such as ICRP...
متن کاملAnatomical Evaluation of Renal Arteries and Veins in Kidney Donors by CT Angiography
Abstract Background: Renal transplantation (RT) is the transplantation of a kidney into a patient with end-stage renal disease and has become the treatment of choice for most patients with end-stage renal disease. The knowledge of renal vascular variations is of a great importance for the surgeons who approach the kidneys from the retroperitoneal o...
متن کاملAssessment of patient entrance skin dose (ESD) and effective dose (ED) for the most common interventional radiological exams at Mazandaran hospital
Introduction: Nowadays we are witnessing an exponential application of interventional radiology techniques in various communities as well as Iran. Radiological technique is regarded as the 2nd contributing factor in increasing the amount of public doses in various societies. So that related radiation protection organization has recommended measuring patient d...
متن کامل