Experimental Study on Damping Ratios of in-situ Buildings
نویسندگان
چکیده
Accurate evaluation of damping ratios involving soilstructure interaction (SSI) effects is the prerequisite for seismic design of in-situ buildings. This study proposes a combined approach to identify damping ratios of SSI systems based on ambient excitation technique. The proposed approach is illustrated with main test process, sampling principle and algorithm steps through an engineering example, as along with its feasibility and validity. The proposed approach is employed for damping ratio identification of 82 buildings in Xi’an, China. Based on the experimental data, the variation range and tendency of damping ratios of these SSI systems, along with the preliminary influence factor, are shown and discussed. In addition, a fitting curve indicates the relation between the damping ratio and fundamental natural period of SSI system. Keyword—Damping ratio, seismic design, soil-structure interaction, system parameter identification.
منابع مشابه
A comparison between modal damping ratios identified by NExT-ERA and frequency domain impact test
In this research, the modal parameters of a beam in free-free condition are extracted by performing different experiments in laboratory. For this purpose, two different techniques are employed. The first methodology is considered as a time domain method in Operational Modal Analysis. While the other one is frequency domain impact hammer test which is categorized as an Experimental Modal Analysi...
متن کاملDynamic Characteristics of Functionalized Carbon Nanotube Reinforced Epoxy Composites: An Experimental Approach
The effects of amine functionalization of carbon nanotubes (CNTs) and CNTs weight percent (wt. %), on the first bending natural frequencies and damping properties of CNT/epoxy composites are investigated in this paper. CNTs and amine functionalized CNTs (AFCNTs), with two different weight percentages, are used to manufacture the beam shaped specimens. Epoxy, CNT/epoxy (0.25 and 0.5 wt. % of CNT...
متن کاملDamped DQE Model Updating of a Three-Story Frame Using Experimental Data
In this paper, following a two-stage methodology, the differential quadrature element (DQE) model of a three-story frame structure is updated for the vibration analysis. In the first stage, the mass and stiffness matrices are updated using the experimental natural frequencies. Then, having the updated mass and stiffness matrices, the structural damping matrix is updated to minimize the error be...
متن کاملEvaluating Equivalent Damping and Response Modification Factors of Frames Equipped by Pall Friction Dampers
A study on the evaluating equivalent damping and response modification factors of frames equipped by Pall Friction Dampers is presented. To do so, buildings with various stories were considered. Nonlinear and linear dynamic time history analysis has been performed to evaluate equivalent damping for Pall Friction Dampers. Ground motions with various frequency characteristics scaled with Iranian ...
متن کاملInfluence of In-Situ Scaling on Variability of Polluted Soil Erodibility Parameters
Middle and southern Iraq suffers from polluted soils due to crude oil, spilled on land, leakage from transmitting pipe networks, or petroleum products from refineries. Many researchers have studied pollution impacts on the soil in details, but there is a clear lack of investigation on the influence of crude oil on soil erodibility. Recent researches have investigated the influence of pollution ...
متن کامل