Evaluation of a quality control phantom for digital chest radiography

نویسندگان

  • Eugene Mah
  • Ehsan Samei
  • Donald J. Peck
چکیده

RATIONALE AND OBJECTIVES To examine the effectiveness and suitability of a quality control (QC) phantom for a routine QC program in digital radiography. MATERIALS AND METHODS The chest phantom consists of copper and aluminum cutouts arranged to resemble the appearance of a chest. Performance of the digital radiography (DR) system is evaluated using high and low contrast resolution objects placed in the "heart," "lung," and "subdiaphragm" areas of the phantom. In addition, the signal levels from these areas were compared to similar areas from clinical chest radiographs. RESULTS The test objects included within the phantom were effective in assessing image quality except within the subdiaphragm area, where most of the low contrast disks were visible. Spatial resolution for the DR systems evaluated with the phantom ranged from 2.6 lp/mm to 4 lp/mm, falling within the middle of the line pair range provided. The signal levels of the heart and diaphragm regions relative to the lung region of the phantom were significantly higher than in clinical chest radiographs (0.67 versus 0.21 and 0.28 versus 0.10 for the heart and diaphragm regions, respectively). The heart-to-diaphragm signal level ratio, however, was comparable to those in clinical radiographs. CONCLUSION The findings suggest that the attenuation characteristics of the phantom are somewhat different from actual chests, but this did not appear to affect the post-processing used by the imaging systems and usefulness for QC of these systems. The qualitative and quantitative measurements on the phantom for different systems were similar, suggesting that a single phantom can be used to evaluate system performance in a routine QC program for a wide range of digital radiography systems. This makes the implementation of a uniform QC program easier for institutions with a mixture of different digital radiography systems.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Patient effective dose evaluation for chest X-ray examination in three digital radiography centers

Background: The radiation doses resulting from diagnostic X-ray examinations are routinely measured in terms of entrance surface dose (ESD) and effective dose (ED). In this study, for the purpose of radiation protection, the radiation doses received from Digital chest X-ray examination were evaluated in terms of ESD and ED. Material and Methods: The ED was calculated by using the MCNP ...

متن کامل

A Phantom Study for the Optimization of Image Quality and Radiation Dose for Common Radiographic Examinations in Digital Radiography

Introduction: Phantom studies facilitate the implementation of radiation dose surveillance as a function of radiographic technical parameters for minimizing patient radiation dose. The evidence of such investigations can then be used to evaluate technical parameters used in the radiographic procedures to reduce radiation dose without compromising the image quality. Material and Methods: This ex...

متن کامل

Construction of an Equivalent Chest Homogeneous Phantom for Evaluation of Image Quality in Pediatric Radiography

Introduction: The purpose of this study is to build homogeneous equivalent phantom chest in order to provide the necessary ability for checking the image quality in radiographic tests in four age groups of children in terms of the most recent age group categorization ICRP103. This phantom provides the features of weakness and discrepancies similar to body and can be consi...

متن کامل

Optimization of Dose and Image Quality in Full-fiand Computed Radiography Systems for Common Digital Radiographic Examinations

IntroductionA fine balance of image quality and radiation dose can be achieved by optimization to minimize stochastic and deterministic effects. This study aimed in ensuring that images of acceptable quality for common radiographic examinations in digital imaging were produced without causing harmful effects. Materials and MethodsThe study was conducted in three phases. The pre-optimization inv...

متن کامل

Primary efforts to optimize image quality in chest direct digital radiography of pediatric patient (for the age group 0 to 1 and 1 to 5 years) with survey some effective parameters in image quality and patient dose

Introduction: This study, evaluate pediatric digital radiography. Due to the high rates of this test and the high sensitivity of children to ionizing radiation in comparison with adults, it is attempted to achieve near optimal conditions by reducing the dose and maintaining the image quality. The object of the study is to change the irradiation parameters such as kV and mA and ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2  شماره 

صفحات  -

تاریخ انتشار 2001