A gradient-layer calorimeter for measurement of energy expenditure of infants.

نویسندگان

  • S J Meis
  • E L Dove
  • E F Bell
  • C M Thompson
  • M A Glatzl-Hawlik
  • A L Gants
  • W K Kim
چکیده

We have developed and validated a gradient-layer calorimeter for direct measurement of energy expenditure of preterm infants. Infant calorimeters must be operated and tested differently from adult calorimeters, because the calorimeter must be warmed during operation to limit heat loss from the infant, the calorimeter wall temperature (which is selected on the basis of the infant's maturity) must be precisely controlled, and energy expenditure (heat output) is typically < 10 W. We calibrated our calorimeter by varying the heat produced by a dry source (manikin or light bulb) with airflow (n = 42) and without airflow (n = 8) at various water jacket temperatures (n = 7) and by a wet source (combustion of ethyl alcohol) with airflow (n = 9). With no air moving, qc = 0.740 Vc + 0.029 Twj-0.697, where qc (W) is the estimated output of the heat source measured by the calorimeter, Vc (mV) is the gradient-layer voltage of the calorimeter, and Twj (degree C) is the temperature of the water jacket surrounding the walls of the device. From this equation and enthalpy calculations, the slope and intercept of the regression line relating the estimated heat production to the actual heat produced from alcohol combustion are 1.029 +/- 0.046 and -0.549 +/- 0.484 (SE), respectively. The slope is not significantly different from unity, and the intercept is not significantly different from zero. Thus we can accurately estimate the energy expenditure of preterm infants from the equations describing our calorimeter, and we can accurately resolve the total heat output into a dry (nonevaporative) component and a wet (evaporative) component.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Synchronous direct gradient layer and indirect room calorimetry.

A dual direct/indirect room-sized calorimeter is used at the Beltsville Human Nutrition Research Center to measure heat emission and energy expenditure in humans. Because the response times of a gradient layer direct calorimeter and an indirect calorimeter are not equivalent, the respective rate of heat emission and energy expenditure cannot be directly compared. A system of equations has been ...

متن کامل

Data Quality Control and Improvement of Indirect Human Calorimeter by System Dynamics Approach J. Futami &H. Kashiwazaki Data Quality Control and Improvement of Indirect Human Calorimeter by System Dynamics Approach

Using a system dynamics approach, a simulation model for data quality control and improvement of human calorimeter using the indirect calorimetry (IHC: indirect human calorimeter) was constructed. Accurate measurements of human energy expenditure are necessary in estimating appropriate energy requirement. IHC can measure continuously energy expenditure over 24 hours. O2 and CO2 analyzers and fl...

متن کامل

Metabolic rate in febrile infants.

An open circuit indirect calorimeter was used to measure resting energy expenditure in febrile infants. Twelve infants admitted to hospital with fever (axillary temperature 37.5 degrees C) were studied on admission and then again at the same time of day and in similar environmental conditions after the fever had resolved. Mean age of the infants was 0.31 years (range 0.12-0.54) and the mean bod...

متن کامل

A human calorimeter for the direct and indirect measurement of 24 h energy expenditure.

1. A calorimeter for the continuous measurement of heat production and heat loss in the human subject, for at least 24 h, is described. The calorimeter operated on the heat-sink principle for direct calorimetry and an open-circuit system for indirect calorimetry. 2. Sensible heat loss was measured using a water-cooled heat exchanger, and the temperature of water entering the heat exchanger was ...

متن کامل

Assessment of the heart-rate method for determining energy expenditure in man, using a whole-body calorimeter.

1. The heart-rate (HR) method for determining the energy expenditure of free-living subjects has been evaluated using a whole-body calorimeter in which individuals lived continuously for 27 h while carrying out normal daily activities. Eight male volunteers each occupied the calorimeter on at least two occasions when HR and energy expenditure were measured continuously. 2. After each session in...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The American journal of physiology

دوره 266 3 Pt 2  شماره 

صفحات  -

تاریخ انتشار 1994