Predictive value of methicillin-resistant Staphylococcus aureus (MRSA) nasal swab PCR assay for MRSA pneumonia.

نویسندگان

  • Benjamin Dangerfield
  • Andrew Chung
  • Brandon Webb
  • Maria Teresa Seville
چکیده

Pneumonia due to methicillin-resistant Staphylococcus aureus (MRSA) is associated with poor outcomes and frequently merits empirical antibiotic consideration despite its relatively low incidence. Nasal colonization with MRSA is associated with clinical MRSA infection and can be reliably detected using the nasal swab PCR assay. In this study, we evaluated the performance of the nasal swab MRSA PCR in predicting MRSA pneumonia. A retrospective cohort study was performed in a tertiary care center from January 2009 to July 2011. All patients with confirmed pneumonia who had both a nasal swab MRSA PCR test and a bacterial culture within predefined time intervals were included in the study. These data were used to calculate sensitivity, specificity, positive predictive value, and negative predictive value for clinically confirmed MRSA pneumonia. Four hundred thirty-five patients met inclusion criteria. The majority of cases were classified as either health care-associated (HCAP) (54.7%) or community-acquired (CAP) (34%) pneumonia. MRSA nasal PCR was positive in 62 (14.3%) cases. MRSA pneumonia was confirmed by culture in 25 (5.7%) cases. The MRSA PCR assay demonstrated 88.0% sensitivity and 90.1% specificity, with a positive predictive value of 35.4% and a negative predictive value of 99.2%. In patients with pneumonia, the MRSA PCR nasal swab has a poor positive predictive value but an excellent negative predictive value for MRSA pneumonia in populations with low MRSA pneumonia incidence. In cases of culture-negative pneumonia where initial empirical antibiotics include an MRSA-active agent, a negative MRSA PCR swab can be reasonably used to guide antibiotic de-escalation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Molecular Characterization and SCCmec in Methicillin Resistant Staphylococcus aureus from Healthy Worker Nasal Swab in Larestan Hospital

Background and Aims: The aim of present study was to investigate the molecular characteristic of Staphylococcus aureus to detect mec A gene and to type SCCmec in strain isolated from healthy worker at Larestan Hospital. Material and Methods: This study was carried out from the 250 nasal swab healthy worker  at Larestan hospital. Multiplex polymerase chain reaction for mecA gene was perf...

متن کامل

Evaluation of the BD GeneOhm MRSA and VanR Assays as a Rapid Screening Tool for Detection of Methicillin-Resistant Staphylococcus aureus and Vancomycin-Resistant Enterococci in a Tertiary Hospital in Saudi Arabia

Objectives. The aim of this study was to evaluate the diagnostic performance of BD GeneOhm VanR Assay, a rapid PCR test that detects the presence of vanA and/or vanB genes and the performance of BDGeneOhm MRSA Assay which detects the staphylococcal cassette chromosomemec (SCCmec cassette) carrying the mecA gene and Staphylococcus aureus specific sequence located within the orfX gene. Methods. 3...

متن کامل

Comparative Evaluation of Three Chromogenic Media Combined with Broth Enrichment and the Real-Time PCR-Based Xpert MRSA Assay for Screening of Methicillin-Resistant Staphylococcus aureus in Nasal Swabs

BACKGROUND We evaluated the performance of three chromogenic media (Brilliance agar I [Oxoid, UK], Brilliance agar II [Oxoid], and ChromID MRSA [Biomérieux, France]) combined with broth enrichment and the Xpert MRSA assay for screening of methicillin-resistant Staphylococcus aureus (MRSA). METHODS We obtained 401 pairs of duplicate nasal swabs from 321 patients. One swab was suspended overnig...

متن کامل

Comparison of BD GeneOhm methicillin-resistant Staphylococcus aureus (MRSA) PCR versus the CHROMagar MRSA assay for screening patients for the presence of MRSA strains.

We compared the BD GeneOhm methicillin-resistant Staphylococcus aureus (MRSA) real-time PCR assay with the CHROMagar MRSA assay for the detection of MRSA in 286 nasal surveillance specimens. Compared with the CHROMagar MRSA assay, PCR had sensitivity, specificity, positive predictive value, and negative predictive values of 100%, 98.6%, 95.8%, and 100%, respectively. The mean PCR turnaround tim...

متن کامل

Comparison of two versions of the IDI-MRSA assay using charcoal swabs for prospective nasal and nonnasal surveillance samples.

An updated IDI-MRSA assay version was released to address the assay's low positive predictive value (PPV). A prospective analysis of two assay versions indicated no significant improvement in the PPV. Colonization by methicillin-resistant Staphylococcus aureus in 24% of patients would not have been detected if only nasal samples had been tested, as approved, by this molecular method.

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Antimicrobial agents and chemotherapy

دوره 58 2  شماره 

صفحات  -

تاریخ انتشار 2014