Evaluating the Mechanical Behavior of Arterial Tissue using Digital Image Correlation

نویسندگان

  • Dongsheng Zhang
  • Charles D. Eggleton
  • Dwayne D. Arola
چکیده

In this study, digital image correlation (DIC) was adopted to examine the mechanical behavior of arterial tissue from bovine aorta. Rectangular sections comprised of the intimal and medial layers were excised from the descending aorta and loaded in displacement control uniaxial tension up to 40 percent elongation. Specimens of silicon rubber sheet were also prepared and served as a benchmark material in the application of DIC for the evaluation of large strains; the elastomer was loaded to 50 percent elongation. The arterial specimens exhibited a non-linear hyperelastic stress–strain response and the stiffness increased with percent elongation. Using a bilinear model to describe the uniaxial behavior, the average minor and major elastic modulii were 192±8 KPa and 912±40 KPa, respectively. Poisson’s ratio of the arterial sections increased with the magnitude of axial strain; the average Poisson’s ratio was 0.17±0.02. Although the correlation coefficient obtained from image correlation decreased with the percent elongation, a correlation coefficient greater than 0.8 was achieved for the tissue experiments and exceeded that obtained in the evaluation of the elastomer. Based on results from this study, DIC may serve as a valuable method for the determination of mechanical properties of arteries and other soft tissues. KEY WORDS—Artery, digital image correlation (DIC), soft tissue

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Stress Field Analysis of V-Notches with Tip Cracks in a Polymer Material Using Digital Image Correlation

In this study, displacement field around v-notches of a poly methyl metha crylate (PMMA) specimen with tip cracks will be analyzed using digital image correlation technique. First intensity factor in combination with in-plane rigid body translations and rotation components will be determined by linear least squares fitting of the displacement field data to the corresponding relations among stre...

متن کامل

Displacement monitoring of a Long-Span Arch Railway Bridge using Digital Image Correlation (DIC)

There is an escalating demand for condition monitoring enhancement of transport infrastructures worldwide. Bridges are of vital importance in transportation infrastructure and need such monitoring. In this research, a non-contact vision-based technique called Digital Image Correlation (DIC) was used to calculate the bridge displacements. A high frame rate camera with 4K capability was used for ...

متن کامل

Applications of digital image correlation to biological tissues.

Optical methods are becoming commonplace in investigations of the physical and mechanical behavior of biological tissues. Digital image correlation (DIC) is a versatile optical method that shows tremendous promise for applications involving biological tissues and biomaterials. We present the fundamentals of DIC with an emphasis on the application to biological materials. An approach for surface...

متن کامل

On the Use of Acoustic Emission and Digital Image Correlation for Welded Joints Damage Characterization

A series of tests have been conducted to investigate fatigue damage characterization in corroded welded steel plates using structural health monitoring (SHM) techniques. Acoustic Emission (AE) is a non-destructive testing (NDT) technique with potential applications for locating and monitoring fatigue cracks in service. In the present work, AE is implemented to characterize damage during crack e...

متن کامل

A method for characterizing the mechanical behaviour of hoof horn

The hoof plays an important role in the health and well-being of dairy animals. Consequently, mechanical properties of the hoof horn and changes in this tissue with nutrition or environmental factors are important concerns. A novel experimental approach for evaluating the mechanical behaviour of hoof horn has been developed. The process is comprised of obtaining incremental slices of hoof horn,...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2002