A new approach for the pistoning measurement in transtibial prosthesis.

نویسندگان

  • Hossein Gholizadeh
  • Noor Azuan Abu Osman
  • Ása Gulaug Lúvíksdóttir
  • Arezoo Eshraghi
  • Mojtaba Kamyab
  • Wan Abu Bakar Wan Abas
چکیده

BACKGROUND Good suspension lessens the pistoning (vertical displacement) of the residual limb inside the prosthetic socket. Several methods are used for measuring the pistoning. STUDY DESIGN Clinical trial. OBJECTIVES To introduce and evaluate a new simple method for measuring the pistoning between the soft liner and socket in transtibial prostheses. METHODS Five transtibial prostheses with Iceross silicone liner and shuttle lock were made for the subjects. The pistoning was measured between the liner and socket by a photographic method in single limb support on the prosthetic limb (full weight bearing), non-weight bearing and under three static axial loading conditions (30, 60 and 90 N). RESULTS This new method enabled us to measure the pistoning between the liner and prosthetic socket. The reproducibility of measurements in different trials of one session and between two sessions by two observers was shown to be high. The average of displacement between the liner and socket was about 9 mm in non-weight bearing compared with full weight bearing. Furthermore, as we expected, the average of pistoning increased consistently by adding the loads. CONCLUSIONS This new method provides for easy and inexpensive determination of pistoning between the liner and socket by every prosthetist in clinical settings.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Transtibial prosthetic socket pistoning: static evaluation of Seal-In(®) X5 and Dermo(®) Liner using motion analysis system.

BACKGROUND The method of attachment of prosthesis to the residual limb (suspension) and socket fitting is a critical issue in the process of providing an amputee with prosthesis. Different suspension methods try to minimize the pistoning movement inside the socket. The Seal-In(®) X5 and Dermo(®) Liner by Ossur are new suspension liners that intend to reduce pistoning between the socket and line...

متن کامل

Transtibial prosthetic suspension: less pistoning versus easy donning and doffing.

Poor suspension increases slippage of the residual limb inside the socket during ambulation. The main purpose of this article is to evaluate the pistoning at the prosthetic liner-socket interface during gait and assess patients' satisfaction with two different liners. Two prostheses with seal-in and locking liners were fabricated for each of the 10 subjects with transtibial amputation. The Vico...

متن کامل

Re: "Quantitative and Qualitative Comparison of a New Prosthetic Suspension System with Two Existing Suspension Systems for Lower Limb Amputees".

OBJECTIVE The objectives of this study were to compare the effects of a newly designed magnetic suspension system with that of two existing suspension methods on pistoning inside the prosthetic socket and to compare satisfaction and perceived problems among transtibial amputees. DESIGN In this prospective study, three lower limb prostheses with three different suspension systems were fabricat...

متن کامل

A clinical comparison between two common transtibial Prosthetic suspension systems

Introduction: Proper fitting of the stump inside the socket and appropriate selection of prosthetic suspension have positive effects on amputees’ satisfaction and could decrease gait deviation, skin problems, and stump atrophy. The suction sockets are commonly prescribed for transtibial amputees to have better suspension compared to the Pin and lock systems. The Seal-In® X5 (suction system) is ...

متن کامل

Development and Evaluation of New Coupling System for Lower Limb Prostheses with Acoustic Alarm System

Individuals with lower limb amputation need a secure suspension system for their prosthetic devices. A new coupling system was developed that is capable of suspending the prosthesis. The system's safety is ensured through an acoustic alarm system. This article explains how the system works and provides an in vivo evaluation of the device with regard to pistoning during walking. The system was d...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Prosthetics and orthotics international

دوره 35 4  شماره 

صفحات  -

تاریخ انتشار 2011