Triggering of the ventilator in patient-ventilator interactions.
نویسنده
چکیده
With current ventilator triggering design, in initiating ventilator breaths patient effort is only a small fraction of the total effort expended to overcome the inspiratory load. Similarly, advances in ventilator pressure or flow delivery and inspiratory flow termination improve patient effort or inspiratory muscle work during mechanical ventilation. Yet refinements in ventilator design do not necessarily allow optimal patient-ventilator interactions, as the clinician is key in managing patient factors and selecting appropriate ventilator factors to maintain patient-ventilator synchrony. In patient-ventilator interactions, unmatched patient flow demand by ventilator flow delivery results in flow asynchrony, whereas mismatches between mechanical inspiratory time (mechanical T(I)) and neural T(I) produce timing asynchrony. Wasted efforts are an example of timing asynchrony. In the triggering phase, trigger thresholds that are set too high or the type of triggering methods induces wasted efforts. Wasted efforts can be aggravated by respiratory muscle weakness or other conditions that reduce respiratory drive. In the post-triggering phase, ventilator factors play an important role in patient-ventilator interaction; this role includes the assistance level, set inspiratory flow rate, T(I), pressurization rate, and cycling-off threshold, and to some extent, applied PEEP. This paper proposes an algorithm that clinicians can use to adjust ventilator settings with the goal to eliminate or reduce patients' wasted efforts.
منابع مشابه
Monitoring of patient-ventilator interaction at the bedside.
Monitoring of patient-ventilator interactions at the bedside involves evaluation of patient breathing pattern on ventilator settings. One goal of mechanical ventilation is to have ventilator-assisted breathing coincide with patient breathing. The objectives of this goal are to have patient breath initiation result in ventilator triggering without undue patient effort, to match assisted-breath d...
متن کاملVentilator with a capnograph smart sensors
Today, the world has witnessed increasing development in various fields, including industry and medicine. One of the best ways to achieve these objectives is the integration of different sciences including electronics, robotics and medicine. Ventilator set that provides respiratory function for patients get smarter and more capable than older generations, during mechanical ventilation to preven...
متن کاملVentilator auto-triggering in a patient with tuberculous bronchopleural fistula.
We report a case of ventilator auto-triggering resulting from tuberculous bronchopleural fistula being managed with chest tube suction. Early recognition of bronchopleural fistula-related auto-triggering is extremely important. Auto-triggering can lead to serious adverse effects, including severe hyperventilation and inappropriate escalation of sedatives and/or neuromuscular blockers (administe...
متن کاملInadvertent triggering of the ventilator caused by surgically placed pacer wires.
Inadvertent ventilator triggering can occur for various reasons. Leaks in the ventilator circuit, endotracheal tube leaks, tracheal cuff leaks, cardiac oscillations, water condensate causing oscillations in the circuit tubing, ventilator expiratory valve integrity, and overly sensitive triggering mechanism settings may precipitate this phenomena. We present a case of inadvertent ventilator trig...
متن کاملIsolation of the Patient from Ventilator
جداسازی بیمار از ونتیلاتور با هدف کاهش حمایت تنفسی وی و برگشت او به سمت تنفس ارادی است. زمان این فرایند با توجه به وضعیت بیمار و مدت اتصال او به دستگاه از چند روز تا چند هفته متغیر خواهد بود.