Measurement of ionised calcium concentration in neonates.

نویسندگان

  • S M Husain
  • N Veligati
  • D G Sims
  • M L Chiswick
  • M Z Mughal
چکیده

Whole blood ionised calcium concentration was measured simultaneously in capillary and arterial blood from neonates being nursed on an intensive care unit using an ion selective electrode. The mean arterio-capillary difference was -0.027 mmol/l (95% confidence intervals -0.041 to -0.012 mmol/l) and the limits of agreement between the two measurements were 0.034 and -0.088 mmol/l. Measurement of ionised calcium in capillary blood is acceptable for clinical purposes.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Serum ionised calcium concentration: measurement versus calculation.

Four hundred and eighteen measurements of serum ionised calcium, total calcium, and protein concentrations were made from 47 normal volunteers, 104 patients with chronic renal failure (33 being treated conservatively and 71 with regular haemodialysis), and 83 renal transplant recipients. The serum ionised calcium concentration was measured with an Orion SS-20 meter and calculated from the total...

متن کامل

Clinical pathology of hypocalcaemia in adult grey parrots (Psittacus e erithacus).

CALCIUM exists in three forms in avian serum: as an ionised salt, bound to proteins and in a complex bound to a variety of anions (citrate, bicarbonate and phosphate). The majority of veterinary pathology laboratories report a total calcium concentration, measured by spectrophotometer, which reflects the total combined levels of ionised calcium, protein-bound calcium and complexed calcium (Bush...

متن کامل

Correlation between serum ionised calcium and serum albumin concentrations in two hospital populations.

One quarter of 172 patients from two hospitals with no obvious disturbances of calcium homeostasis and with total serum calcium concentrations that were normal after adjustment for albumin concentration had low serum ionised calcium concentrations. The low values were not due to changes in pH but were associated with hypoalbuminaemia. Significant positive regressions of ionised calcium on album...

متن کامل

Stability of citrate and calcium dosing in citrate renal replacement therapy

Introduction Citrate is the recommended anticoagulant for continuous renal replacement therapy (RRT) [1], and is thought to confer numerous benefits, including more continuous hours of filtration, fewer total circuits used, less overall cost and maybe improved patient and kidney survival when compared with heparin anticoagulation [2]. Citrate is run pre filter, calcium is infused post filter, t...

متن کامل

A retrospective cohort analysis of ionised calcium levels in major trauma patients who have received early blood product transfusion in the Emergency Department

Background Exsanguination and coagulopathy remain one of the leading causes of preventable trauma related death [1]. Low ionised calcium levels have been associated with hypotension and increased mortality [2]. Blood product contains citrate that acts as a calcium chelating agent. We hypothesized that trauma patients are at risk of hypocalcaemia and blood products given to resuscitate them woul...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Archives of disease in childhood

دوره 69 1 Spec No  شماره 

صفحات  -