A randomized clinical trial about presence of pathogenic microflora and risk of peri-implantitis: comparison of two different types of implant-abutment connections.

نویسندگان

  • F Mencio
  • F De Angelis
  • P Papi
  • D Rosella
  • G Pompa
  • S Di Carlo
چکیده

OBJECTIVE The aim of this in vivo study was to evaluate two different types of implant-abutment connections: screwed connection and cemented connection, analyzing peri-implant bacteria microflora as well as other clinical parameters. PATIENTS AND METHODS Twenty implants were selected, inserted in 20 patients, 10 with a screwed implant-abutment connection (Group 1) and 10 with a cemented implant-abutment connection (Group 2). The peri-implant microflora was collected, after at least 360 days from the prosthetic rehabilitation, using paper points inserted in peri-implant sulcus for 30 s. Polymerase chain reaction (PCR) Real-time analyzed the presence of 9 bacteria periodontal-pathogens and Candida albicans. RESULTS Our findings showed that bacteria colonized all Groups analyzed, the average bacterial count was 3.7 E +08 (±1.19) in Group 1, compared to 2.1 E +08 (±0.16) in Group 2; no statistically significant differences were observed (p>0.0.5). In Group 1, however, bacterial colonization of peri-implant sulci was over the pathogenic threshold for 5 bacteria, indicating a high-risk of peri-implantitis. Also in Group 2, results showed a microflora composed by all bacteria analyzed but, in this case, bacterial colonization of peri-implant sulci was over the pathogenic threshold for only 1 bacterium, indicating a lower risk of peri-implantitis. Moreover, clinical parameters (PPD > 3 mm and m SBI > 0) confirmed a greater risk of peri-implantitis in Group 1 compared to Group 2 (p<0.05). CONCLUSIONS We concluded that, also after only 360 days, implants with screwed connection showed a higher risk of peri-implantitis that implants with cemented connection.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determining the prevalence of peri-implantitis in patients one year after prosthetic loading in Khorramabad in 2021

Background and Aims: Although dental implants have become a successful and predictable ong-term treatment for patients, not all implant treatments are necessarily successful and pre-implant diseases are spreading. The aim of this study was to determine the prevalence of peri-implantitis in patients one year after prosthetic loading in Khorramabad in 2021. Materials and Methods: In this cross-s...

متن کامل

Receptor Activator of Nuclear Factor Kappa B Ligand (RANKL) Levels in Peri-Implant Crevicular Fluid

Background: Receptor activator of nuclear factor kappa B ligand (RANKL) is one of the key cytokines in the induction of osteoclastogenesis both in vitro and in vivo.Several reports indicated the presence of sRANKL in gingival crevicular fluid of patients with periodontal diseases. Objective: To determine the presence of RANKL in peri-implant crevicular fluid samples of implants with peri-implan...

متن کامل

Assessment of Dentists’ knowledge of Peri-Implant Inflammatory Diseases and Their Related Treatment in Rasht

Introdouction: Implants are considered to be a useful treatment for the replacement of lost teeth. Although the success rate and durability of implants are high, the prevalence of peri-implantitis is high as well. The purpose of this study was to analyze the knowledge of general practitioners in the city of Rasht in Northern Iran regarding peri-implantitis and its treatment. Materials and meth...

متن کامل

Effect of implant placement depth on the peri-implant bone defect configurations in ligature-induced peri-implantitis: An experimental study in dogs

BACKGROUND The subcrestal placement of implant platform has been considered a key factor in the preservation of crestal bone, but the influence of implant placement depth on bone remodeling combined with peri-implantitis is not fully understood. The aim of this study was to assess the effect of the crestal or subcrestal placement of implants on peri-implant bone defects of ligature-induced peri...

متن کامل

Comparative Evaluation of Microleakage at the Interface of Titanium and Zirconium Abutments Following Oblique Cyclic Loading: An in vitro Study

Abstract Background and aim: Oral microbiota could proliferate the microspace between the implant and abutment, thereby cause inflammation in the peri-implant tissues and adjacent bone. This study aimed to investigate the effect of two types of abutments (zirconia and titanium) on microleakage at implant-abutment interface area under oblique cyclic loading in vitro. Materials and methods:In thi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European review for medical and pharmacological sciences

دوره 21 7  شماره 

صفحات  -

تاریخ انتشار 2017