Prognostic value of transthoracic coronary flow reserve in medically treated patients with proximal left anterior descending artery stenosis of intermediate severity.

نویسندگان

  • Patrick Meimoun
  • Tahar Benali
  • Frederic Elmkies
  • Smain Sayah
  • Anne Luycx-Bore
  • Luc Doutrelan
  • Zemir Hamdane
  • Jacques Boulanger
  • Christophe Tribouilloy
چکیده

AIMS Prognostic value of transthoracic coronary flow reserve (T-CFR) is not established in patients with left anterior descending artery (LAD) stenosis of intermediate severity. Objective is to determine the prognosis value of T-CFR>2 in medically treated patients with angiographically intermediate [50-70% QCA (quantitative coronary angiography)] proximal LAD stenosis. METHODS AND RESULTS Among 110 consecutive patients with intermediate LAD stenosis who underwent prospectively T-CFR in the distal part of the LAD after intravenous administration of adenosine to assess the functional significance of the stenosis, 80 patients had T-CFR>2 and were treated medically without revascularization (Group 1). Among the 30 patients who had T-CFR<2, an additional dobutamine stress echocardiography (DSE) was performed: 15 had a negative DSE; were treated medically and served as a comparative group (Group 2), and 15 had a positive DSE; underwent LAD revascularization, and were excluded from further analysis. All patients completed follow-up (16+/-10 months). During the follow-up period (range 6-45 months), 76 patients (95%) remained free of death or LAD-related event in Group 1, vs. 12 patients (80%) in Group 2. By Kaplan-Meier method, at 30 months the per cent estimated survival free from death or target vessel-related events was 92+/-4% in Group 1 and 44+/-22% in Group 2 (P<0.01). By multivariate analysis, T-CFR remained the only independent predictor of death or LAD-related events. CONCLUSION In patients with proximal LAD stenosis of intermediate severity and T-CFR>2, deferral of revascularization is associated with low event rate.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Non-invasive measurement of coronary flow reserve in children with Kawasaki disease.

OBJECTIVE To investigate whether transthoracic Doppler echocardiography (TTE) can reliably measure the coronary flow reserve in the left anterior descending coronary artery in children with Kawasaki disease. DESIGN Coronary flow velocity in the distal left anterior descending coronary artery was measured by TTE and was compared with that obtained by intracoronary Doppler guide wire. The ratio...

متن کامل

2150 Correlation of Pharmacological 99 mTcwSestamibi Myocardial Perfusion Imaging With Poststenotic Coronary Flow Reserve in Patients With Angiographically Intermediate Coronary Artery Stenoses

Backgrnd The physiological assessment of angiographically intermediate-severity stenoses remains problematic. Functional measurements of poststenotic intracoronary Doppler coronary flow reserve can be performed in humans but have not been correlated with hyperemic myocardial perfusion imaging or angiographic data in this patient population. Method and Resus Thirty-three patients undergoing diag...

متن کامل

Correlation of Pharmacological 99 mTcwSestamibi Myocardial Perfusion Imaging With Poststenotic Coronary Flow Reserve in Patients With Angiographically Intermediate Coronary Artery Stenoses

Backgrnd The physiological assessment of angiographically intermediate-severity stenoses remains problematic. Functional measurements of poststenotic intracoronary Doppler coronary flow reserve can be performed in humans but have not been correlated with hyperemic myocardial perfusion imaging or angiographic data in this patient population. Method and Resus Thirty-three patients undergoing diag...

متن کامل

Correlation of Pharmacological 99 mTcwSestamibi Myocardial Perfusion Imaging With Poststenotic Coronary Flow Reserve in Patients With Angiographically Intermediate Coronary Artery

Backgrnd The physiological assessment of angiographically intermediate-severity stenoses remains problematic. Functional measurements of poststenotic intracoronary Doppler coronary flow reserve can be performed in humans but have not been correlated with hyperemic myocardial perfusion imaging or angiographic data in this patient population. Method and Resus Thirty-three patients undergoing diag...

متن کامل

Transthoracic ultrasonic tissue indices identify patients with severe left anterior descending artery stenosis. Correlation with fractional flow reserve. Pilot study.

BACKGROUND AND AIM The aim of this study was to evaluate the potential clinical application of ultrasonic tissue indices, with a focus on systolic strain (SS) and systolic strain rate (SSR) parameters derived from transthoracic echocardiography, in the assessment of left anterior descending artery (LAD) stenosis. METHODS The data of 30 patients with significant LAD stenosis were analysed. All...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • European journal of echocardiography : the journal of the Working Group on Echocardiography of the European Society of Cardiology

دوره 10 1  شماره 

صفحات  -

تاریخ انتشار 2009